The accuracy of single serum progesterone measurement in the diagnosis of ectopic pregnancy: a meta-analysis

被引:112
作者
Mol, BWJ
Lijmer, JG
Ankum, WM
van der Veen, F
Bossuyt, PMM
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1100 DE Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Reprod Med, NL-1100 DE Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Obstet & Gynaecol, NL-1100 DE Amsterdam, Netherlands
关键词
diagnosis; ectopic pregnancy; meta-analysis; serum progesterone measurement;
D O I
10.1093/humrep/13.11.3220
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Serum progesterone measurement has been advocated as a diagnostic tool in the non-invasive diagnosis of ectopic pregnancy, To assess the accuracy of a single serum progesterone measurement in the diagnosis of ectopic pregnancy, a meta-analysis was performed incorporating 26 studies evaluating the performance of single serum progesterone measurement in the diagnosis of ectopic pregnancy. A distinction was made in the diagnosis of pregnancy failure of any type versus viable intrauterine pregnancy and the diagnosis of ectopic pregnancy versus non-ectopic pregnancy. The reported sensitivity and specificity differed between the studies. Since there was a clear negative correlation between sensitivity and specificity, summary receiver-operating characteristic (ROC) curves could be estimated. The ROC curve for the diagnosis of pregnancy failure versus viable intrauterine pregnancy showed a good discriminative capacity. Single serum progesterone measurement could not discriminate between ectopic pregnancy and non-ectopic pregnancy, It is concluded that serum progesterone measurement can identify patients at risk for ectopic pregnancy, who need further evaluation, but its discriminative capacity is insufficient to diagnose ectopic pregnancy with certainty.
引用
收藏
页码:3220 / 3227
页数:8
相关论文
共 44 条
[1]   THE ROLE OF A SINGLE PROGESTERONE MEASUREMENT IN THE DIAGNOSIS OF EARLY-PREGNANCY FAILURE AND THE PROGNOSIS OF FETAL VIABILITY [J].
ALSEBAI, MAH ;
KINGSLAND, CR ;
DIVER, M ;
HIPKIN, L ;
MCFADYEN, IR .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (05) :364-369
[2]  
BUCK RH, 1988, FERTIL STERIL, V50, P752
[3]  
CARSON SA, 1993, NEW ENGL J MED, V329, P1174
[4]   SERUM PROGESTERONE AND 17-HYDROXYPROGESTERONE IN THE DIAGNOSIS OF ECTOPIC PREGNANCIES AND THE VALUE OF PROGESTERONE REPLACEMENT IN INTRAUTERINE PREGNANCIES WHEN SERUM PROGESTERONE LEVELS ARE LOW [J].
CHOE, JK ;
CHECK, JH ;
NOWROOZI, K ;
BENVENISTE, R ;
BARNEA, ER .
GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1992, 34 (03) :133-138
[5]   RECEIVER-OPERATOR CHARACTERISTIC, EFFICIENCY ANALYSIS, AND PREDICTIVE VALUE OF SERUM PROGESTERONE CONCENTRATION AS A TEST FOR ABNORMAL GESTATIONS [J].
COWAN, BD ;
VANDERMOLEN, DT ;
LONG, CA ;
WHITWORTH, NS .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 166 (06) :1729-1737
[6]   THE PROGNOSTIC VALUE OF SERUM PROGESTERONE AND QUANTITATIVE BETA-HUMAN CHORIONIC-GONADOTROPIN IN EARLY HUMAN-PREGNANCY [J].
DAILY, CA ;
LAURENT, SL ;
NUNLEY, WC .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (02) :380-384
[7]   Is maternal serum creatine kinase actually a marker for early diagnosis of ectopic pregnancy? [J].
Darai, E ;
Vlastos, G ;
Benifla, JL ;
Sitbon, D ;
Hassid, J ;
Dehoux, M ;
Madelenat, P ;
Gaucher, GD ;
Nunez, E .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1996, 68 (1-2) :25-27
[8]  
GELDER MS, 1991, FERTIL STERIL, V55, P497
[9]  
GROSSKINSKY CM, 1993, OBSTET GYNECOL, V81, P705
[10]  
GUILLAUME J, 1990, OBSTET GYNECOL, V76, P1126