Determination of iodine value with a Fourier transform-near infrared based global calibration using disposable vials: An international collaborative study

被引:25
作者
Cox, R
Lebrasseur, J
Michiels, E
Buijs, H
Li, H
van de Voort, FR
Ismail, AA
Sedman, J
机构
[1] ABB Bomem, Quebec City, PQ G1K 9H4, Canada
[2] McGill Univ, Dept Food Sci & Agr Chem, McGill IR Grp, St Anne De Bellevue, PQ H9X 3V9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
discriminate analysis; disposable vial sampling; fats and oils; Fourier transform-near infrared spectroscopy; global calibration; iodine value (IV); partial least squares;
D O I
10.1007/s11746-000-0192-4
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method for the determination of iodine value (IV) by Fourier transform-near infrared (FT-NIR) spectroscopy was developed and evaluated in an international collaborative study. The FT-NIR analyzer employed in this work uses disposable vials for sample handling and incorporates validation protocols designed to ensure that the calibration will give accurate results from analyzer to analyzer and stability over time without any further calibration development work. The global IV calibration was developed from over 1,200 animal, marine, and vegetable oils and fats, which were obtained on a number of different instruments worldwide. The Standard Error of Cross Validation measured from a range of 0-190 IV varied from +/-0.2-1.4 IV(1 sigma). The repeatability for all models was on the order of 0.1 IV, which states that most of the error was inherited from the primary methods. Finally, an international interlaboratory study was carried out with 16 samples obtained from the AOCS Smalley Laboratory Proficiency Program and an oil processor. The average reproducibility error in any one lab was better than 0.15, and the average reproducibility between labs was better than 0.33. An uncertainty of 0.45 was calculated from the average FT-NIR values obtained from the collaborative study vs. the AOCS Certified Wijs method (Cd 1d-92).
引用
收藏
页码:1229 / 1234
页数:6
相关论文
共 7 条
[1]  
*BOM INC, 1999, GLOB IOD VAL CAL OIL
[2]  
Dong J, 1997, J AOAC INT, V80, P345
[3]  
Firestone D, 1998, OFFICIAL METHODS REC
[4]   Trans determination of edible oils by Fourier transform near-infrared spectroscopy [J].
Li, H ;
van de Voort, FR ;
Ismail, AA ;
Sedman, J ;
Cox, R .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2000, 77 (10) :1061-1067
[5]   Determination of peroxide value by Fourier transform near-infrared spectroscopy [J].
Li, H ;
van de Voort, FR ;
Ismail, AA ;
Cox, R .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2000, 77 (02) :137-142
[6]   Rapid determination of cis and trans content, iodine value, and saponification number of edible oils by Fourier transform near-infrared spectroscopy [J].
Li, H ;
van deVoort, FR ;
Sedman, J ;
Ismail, AA .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1999, 76 (04) :491-497
[7]   Discrimination of edible oil products and quantitative determination by Fourier transform near-infrared spectroscopy [J].
Li, H ;
van de Voort, FR ;
Ismail, AA ;
Sedman, J ;
Cox, R ;
Simard, C ;
Buijs, H .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2000, 77 (01) :29-36