Megapixel ion imaging with standard video

被引:163
作者
Li, W
Chambreau, SD
Lahankar, SA
Suits, AG [1 ]
机构
[1] Wayne State Univ, Dept Chem, Detroit, MI 48202 USA
[2] SUNY Stony Brook, Dept Chem, Stony Brook, NY 11794 USA
基金
美国国家科学基金会;
关键词
D O I
10.1063/1.1921671
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present an ion imaging approach employing a real-time ion counting method with standard video. This method employs a center-of-mass calculation of each ion spot (more than 3x3 pixels spread) prior to integration. The results of this algorithm are subpixel precision position data of the corresponding ion spots. These addresses are then converted to the final image with user selected resolution, which can be up to ten times higher than the standard video camera resolution (640x480). This method removes the limiting factor imposed by the resolution of standard video cameras and does so at very low cost. The technique is used in conjunction with dc slice imaging, replacing the local maximum searching algorithm developed by Houston and co-workers [B. Y. Chang, R. C. Hoetzlein, J. A. Mueller, J. D. Geiser, and P. L. Houston, Rev. Sci. Instrum. 69, 1665 (1998)]. The performance is demonstrated using HBr and DBr photodissociation at 193 nm with 3+1 resonance enhanced multiphoton ionization detection of hydrogen and deuterium atom products. The measured velocity resolution for DBr dissociation is 0.50% (delta v/v), mainly limited in this case by the bandwidth of the photolysis laser. Issues affecting slice imaging resolution and performance are also discussed. (c) 2005 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 18 条
[1]   RESONANCE-ENHANCED MULTIPHOTON IONIZATION OF ATOMIC-HYDROGEN [J].
BREWER, LR ;
BUCHINGER, F ;
LIGARE, M ;
KELLEHER, DE .
PHYSICAL REVIEW A, 1989, 39 (08) :3912-3923
[2]   TWO-DIMENSIONAL IMAGING OF STATE-SELECTED PHOTODISSOCIATION PRODUCTS DETECTED BY MULTIPHOTON IONIZATION [J].
CHANDLER, DW ;
HOUSTON, PL .
JOURNAL OF CHEMICAL PHYSICS, 1987, 87 (02) :1445-1447
[3]   Improved two-dimensional product imaging: The real-time ion-counting method [J].
Chang, BY ;
Hoetzlein, RC ;
Mueller, JA ;
Geiser, JD ;
Houston, PL .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (04) :1665-1670
[4]   Slicing using a conventional velocity map imaging setup:: O2, I2, and I2+ photodissociation [J].
Chestakov, DA ;
Wu, SM ;
Wu, GR ;
Parker, DH ;
Eppink, ATJB ;
Kitsopoulos, TN .
JOURNAL OF PHYSICAL CHEMISTRY A, 2004, 108 (39) :8100-8105
[5]  
*CRC, CRC HDB CHEM PHYS
[6]   Velocity map imaging of ions and electrons using electrostatic lenses: Application in photoelectron and photofragment ion imaging of molecular oxygen [J].
Eppink, ATJB ;
Parker, DH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (09) :3477-3484
[7]   Slice imaging: A new approach to ion imaging and velocity mapping [J].
Gebhardt, CR ;
Rakitzis, TP ;
Samartzis, PC ;
Ladopoulos, V ;
Kitsopoulos, TN .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (10) :3848-3853
[8]  
KOMISARROV A, UNPUB
[9]   Application of time-sliced ion velocity imaging to crossed molecular beam experiments [J].
Lin, JJ ;
Zhou, JG ;
Shiu, WC ;
Liu, KP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (04) :2495-2500
[10]   A magnifying lens for velocity map imaging of electrons and ions [J].
Offerhaus, HL ;
Nicole, C ;
Lépine, F ;
Bordas, C ;
Rosca-Pruna, F ;
Vrakking, MJJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08) :3245-3248