The use of Fourier-transform infrared spectroscopy for the quantitative determination of glucose concentration in whole blood

被引:58
作者
Shen, YC
Davies, AG
Linfield, EH
Elsey, TS
Taday, PF
Arnone, DD
机构
[1] Univ Cambridge, Cavendish Lab, Cambridge CB3 0HE, England
[2] Univ Leeds, Sch Elect & Elect Engn, Leeds LS2 9JT, W Yorkshire, England
[3] Addenbrookes NHS Trust, Cambridge CB2 2QR, England
[4] TeraView Ltd, Cambridge CB4 0WG, England
关键词
D O I
10.1088/0031-9155/48/13/313
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fourier-transform infrared transmission spectroscopy has been used for the determination of glucose concentration in whole blood samples from 28 patients. A 4-vector partial least-squares calibration model, using the spectral range 950-1200 cm(-1), yielded a standard-error-of-prediction of 0.59 mM for an independent test set. For blood samples from a single patient, we found that the glucose concentration was proportional to the difference between the values of the second derivative spectrum at 1082 cm(-1) and 1093 cm(-1). This indicates that spectroscopy at these two specific wavenumbers, alone could be used to determine the glucose concentration in blood plasma samples from a single patient, with a prediction error of 0.95 mM.
引用
收藏
页码:2023 / 2032
页数:10
相关论文
共 21 条
[1]   Non-invasive glucose monitoring [J].
Arnold, MA .
CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) :46-49
[2]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[3]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY [J].
BHANDARE, P ;
MENDELSON, Y ;
PEURA, RA ;
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
APPLIED SPECTROSCOPY, 1993, 47 (08) :1214-1221
[4]   Application of molecular spectroscopy in the mid-infrared region to the determination of glucose and cholesterol in whole blood and in blood serum [J].
Budinova, G ;
Salva, J ;
Volka, K .
APPLIED SPECTROSCOPY, 1997, 51 (05) :631-635
[5]  
Buslov DK, 1999, SPECTROCHIM ACTA A, V55, P229
[6]   REAGENTLESS NEAR-INFRARED DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING MULTIVARIATE CALIBRATION [J].
HAALAND, DM ;
ROBINSON, MR ;
KOEPP, GW ;
THOMAS, EV ;
EATON, RP .
APPLIED SPECTROSCOPY, 1992, 46 (10) :1575-1578
[7]  
HALL JW, 1992, CLIN CHEM, V38, P1623
[8]   Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy [J].
Hazen, KH ;
Arnold, MA ;
Small, GW .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :255-267
[9]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD BY ATTENUATED TOTAL REFLECTION INFRARED-SPECTROSCOPY [J].
HEISE, HM ;
MARBACH, R ;
JANATSCH, G ;
KRUSEJARRES, JD .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2009-2015
[10]   Rapid and reliable spectral variable selection for statistical calibrations based on PLS-regression vector choices [J].
Heise, HM ;
Bittner, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (01) :93-99