MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY

被引:102
作者
BHANDARE, P
MENDELSON, Y
PEURA, RA
JANATSCH, G
KRUSEJARRES, JD
MARBACH, R
HEISE, HM
机构
[1] WORCESTER POLYTECH INST,DEPT BIOMED ENGN,100 INST RD,WORCESTER,MA 01609
[2] KATHARINEN HOSP,INST KLIN CHEM & LAB MED,W-7000 STUTTGART 1,GERMANY
[3] INST SPEKTROCHEM & ANGEW SPEKT,W-4600 DORTMUND 1,GERMANY
关键词
BLOOD GLUCOSE DETERMINATION; IR SPECTROSCOPY; MULTIVARIATE CALIBRATION; CHEMOMETRICS; PARTIAL LEAST-SQUARES; ARTIFICIAL NEURAL NETWORKS;
D O I
10.1366/0003702934067928
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The infrared (IR) spectra of whole blood EDTA samples, in the range between 1500 and 750 cm-1, obtained from the patient population of a general hospital, were used to compare different multivariate calibration techniques for quantitative glucose determination. Ninety-six spectra of whole undiluted blood samples with glucose concentration ranging between 44 and 291 mg/dL were used to create calibration models based on a combination of partial least-squares (PLS) and artificial neural network (ANN) methods. The prediction capabilities of these calibration models were evaluated by comparing their standard errors of prediction (SEP) with those obtained with the use of PLS and principal component regression (PCR) calibration models in an independent prediction set consisting of 31 blood samples. The optimal model based on the combined PLS-ANN produced smaller SEP values (15.6 mg/dL) compared with those produced with the use of either PLS (21.5 mg/dL) or PCR (24.0 mg/dL) methods. Our results revealed that the combined PLS-ANN models can better approximate the deviations from linearity in the relationship between spectral data and concentration, compared with either PLS or PCR models.
引用
收藏
页码:1214 / 1221
页数:8
相关论文
共 34 条
[1]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[2]  
BHANDARE P, 1992, 14TH P ANN INT C IEE, P163
[3]   OPTIMAL MINIMAL NEURAL INTERPRETATION OF SPECTRA [J].
BORGGAARD, C ;
THODBERG, HH .
ANALYTICAL CHEMISTRY, 1992, 64 (05) :545-551
[4]   CONSISTENCY IN CIRCLE CELL FT-IR ANALYSIS OF AQUEOUS-SOLUTIONS [J].
BRAUE, EH ;
PANNELLA, MG .
APPLIED SPECTROSCOPY, 1987, 41 (06) :1057-1067
[5]  
CHATFIELD C, 1980, INTRO MULTIVARIATE A, pCH8
[6]   ABSORBANCE LINEARITY AND REPEATABILITY IN CYLINDRICAL INTERNAL REFLECTANCE FT-IR SPECTROSCOPY OF LIQUIDS [J].
DOYLE, WM .
APPLIED SPECTROSCOPY, 1990, 44 (01) :50-58
[7]   QUANTITATIVE DEPTH PROFILING WITH FOURIER-TRANSFORM INFRARED-SPECTROSCOPY [J].
FINA, LJ ;
CHEN, G .
VIBRATIONAL SPECTROSCOPY, 1991, 1 (04) :353-361
[8]  
Frohlich P, 1920, ANN PHYS-BERLIN, V63, P900
[9]   PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL [J].
GELADI, P ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1986, 185 :1-17
[10]   NONLINEAR MULTIVARIATE CALIBRATION USING PRINCIPAL COMPONENTS REGRESSION AND ARTIFICIAL NEURAL NETWORKS [J].
GEMPERLINE, PJ ;
LONG, JR ;
GREGORIOU, VG .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2313-2323