Behavioral and environmental determinants of personal exposures to PM2.5 in EXPOLIS -: Helsinki, Finland

被引:85
作者
Koistinen, KJ
Hänninen, O
Rotko, T
Edwards, RD
Moschandreas, D
Jantunen, MJ
机构
[1] Natl Publ Hlth Inst, Div Environm Hlth, FI-70701 Kuopio, Finland
[2] IIT, Chicago, IL 60616 USA
[3] EC, Joint Res Ctr, EI, AQU, I-21020 Ispra, VA, Italy
基金
芬兰科学院;
关键词
particulate matter; PM2.5; determinant; personal exposure; ETS; non-ETS; EXPOLIS;
D O I
10.1016/S1352-2310(00)00446-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Behavioral and environmental determinants of PM2.5 personal exposures were analyzed for 201 randomly selected adult participants (25-55 years old) of the EXPOLIS study in Helsinki, Finland. Personal exposure concentrations were higher than respective residential outdoor, residential indoor and workplace indoor concentrations for both smokers and non-smokers. Mean personal exposure concentrations of active smokers (31.0 +/- 31.4 mug m(-3)) were almost double those of participants exposed to environmental tobacco smoke (ETS) (16.6 +/- 11.8 mug m(-3)) and three times those of participants not exposed to tobacco smoke (9.9 +/- 6.21 mug m(-3)). Mean indoor concentrations of PM2.5 when a member of the household smoked indoors (20.8 +/- 23.9 mug m(-3)) were approximately 2.5 times the concentrations of PM2.5 when no smoking was reported (8.2 +/- 5.2 mug m(-3)). Interestingly, however, both mean (8.2 mug m(-3)) and median (6.9 mug m(-3)) residential indoor concentrations for non-ETS exposed participants were lower than residential outdoor concentrations (9.5 and 7.3 mug m(-3), respectively). In simple linear regression models residential indoor concentrations were the best predictors of personal exposure concentrations. Correlations (r(2)) between PM2.5 personal exposure concentrations of all participants, both smoking and non-smoking, and residential indoor, workplace indoor, residential outdoor and ambient fixed site concentrations were 0.53, 0.38, 0.17 and 0.16, respectively. Predictors for personal exposure concentrations of non-ETS exposed participants identified in multiple regression were residential indoor concentrations, workplace concentrations and traffic density in the nearest street from home, which accounted for 77% of the variance. Subsequently, step-wise regression not including residential and workplace indoor concentrations as input las these are frequently not available), identified ambient PM2.5 concentration and home location, as predictors of personal exposure, accounting for 47% of the variance. Ambient fixed site PM2.5 concentrations were closely related to residential outdoor concentrations (r(2) = 0.9, p = 0.000) and PM2.5 personal exposure concentrations were higher in summer than during other seasons. Personal exposure concentrations were significantly (p = 0.040) higher for individuals living downtown compared with individuals in suburban family homes. Further analysis will focus on comparisons of determinants between Helsinki and other EXPOLIS centers. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2473 / 2481
页数:9
相关论文
共 21 条
[1]  
AARNIO P, 1998, ILMANLAATUPAAKAUPUNK
[2]  
ACKERMANNLIEBRI.U, 1995, AIR POLLUTION EPIDEM, V6
[3]   Spatial variation in particulate concentrations within metropolitan Philadelphia [J].
Burton, RM ;
Suh, HH ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (02) :400-407
[4]   MEASUREMENT METHODS TO DETERMINE COMPLIANCE WITH AMBIENT AIR-QUALITY STANDARDS FOR SUSPENDED PARTICLES [J].
CHOW, JC .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (05) :320-382
[5]  
CLAYTON CA, 1993, J EXPO ANAL ENV EPID, V3, P227
[6]  
Jantunen MJ, 1998, J EXPO ANAL ENV EPID, V8, P495
[7]  
JENKINS PL, 1992, ATMOS ENVIRON A-GEN, V26, P2142
[8]   A STUDY TO CHARACTERIZE INDOOR PARTICLES IN 3 NONSMOKING HOMES [J].
KAMENS, R ;
LEE, CT ;
WIENER, R ;
LEITH, D .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1991, 25 (5-6) :939-948
[9]   Fine particle (PM2.5) measurement methodology, quality assurance procedures, and pilot results of the EXPOLIS study [J].
Koistinen, KJ ;
Kousa, A ;
Tenhola, V ;
Hänninen, O ;
Jantunen, MJ ;
Oglesby, L ;
Kuenzli, N ;
Georgoulis, L .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (10) :1212-1220
[10]   SOURCE APPORTIONMENT OF INDOOR AEROSOLS IN SUFFOLK AND ONONDAGA COUNTIES, NEW-YORK [J].
KOUTRAKIS, P ;
BRIGGS, SLK ;
LEADERER, BP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (03) :521-527