Single-photon counting multicolor multiphoton fluorescence microscope

被引:45
作者
Buehler, C
Kim, KH
Greuter, U
Schlumpf, N
So, PTC
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[3] MIT, Biol Engn Div, Cambridge, MA 02139 USA
关键词
multiphoton microscopy; single-photon counting; imaging spectroscopy;
D O I
10.1007/s10895-005-0212-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.
引用
收藏
页码:41 / 51
页数:11
相关论文
共 24 条
[1]   Two-photon laser scanning microscopy of epithelial cell-modulated collagen density in engineered human lung tissue [J].
Agarwal, A ;
Coleno, ML ;
Wallace, VP ;
Wu, WY ;
Sun, CH ;
Tromberg, BJ ;
George, SC .
TISSUE ENGINEERING, 2001, 7 (02) :191-202
[2]   Rapid analysis of Raman image data using two-way multivariate curve resolution [J].
Andrew, JJ ;
Hancewicz, TM .
APPLIED SPECTROSCOPY, 1998, 52 (06) :797-807
[3]   Multi-wavelength TCSPC lifetime imaging [J].
Becker, W ;
Bergmann, A ;
Biskup, C ;
Zimmer, T ;
Klöcker, N ;
Benndorf, K .
MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 :79-84
[4]  
Bennett BD, 1996, J BIOL CHEM, V271, P3647
[5]   Multifocal multiphoton microscopy [J].
Bewersdorf, J ;
Pick, R ;
Hell, SW .
OPTICS LETTERS, 1998, 23 (09) :655-657
[6]   Innovations in two-photon deep tissue microscopy [J].
Buehler, C ;
Kim, KH ;
Dong, CY ;
Masters, BR ;
So, PTC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1999, 18 (05) :23-30
[7]   Multi-color two-photon scanning microscopy using a 16-channel photomultiplier [J].
Buehler, C ;
Kim, KH ;
Greuter, U ;
Schlumpf, N ;
So, PTC .
MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 :217-230
[8]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[9]   Sensitive imaging of spectrally overlapping fluorochromes using the LSM 510 META [J].
Dickinson, ME ;
Waters, CW ;
Bearman, G ;
Wolleschensky, R ;
Tille, S ;
Fraser, SE .
MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES II, 2002, 4620 :123-136
[10]   CONNECTIVE-TISSUE POLARITY - OPTICAL 2ND-HARMONIC MICROSCOPY, CROSSED-BEAM SUMMATION, AND SMALL-ANGLE SCATTERING IN RAT-TAIL TENDON [J].
FREUND, I ;
DEUTSCH, M ;
SPRECHER, A .
BIOPHYSICAL JOURNAL, 1986, 50 (04) :693-712