An evaluation of the quality of root fillings in mandibular incisors and maxillary and mandibular canines using different methodologies

被引:47
作者
van der Sluis, LWM [1 ]
Wu, MK [1 ]
Wesselink, PR [1 ]
机构
[1] Acad Ctr Dent Amsterdam, Dept Cardiol Endodontol Pedodontol, NL-1066 EA Amsterdam, Netherlands
关键词
oval canal; fitting quality; evaluation root canal fittings;
D O I
10.1016/j.jdent.2005.01.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the quality of root fittings in mandibular incisors and maxillary and mandibular canines using different methodologies of evaluation, namely radiographs, the fluid transport test and the percentage of gutta-percha (PGP), and to determine if a correlation occurs between the results of the different methodologies used. Methods: One group of mandibular incisors with oval canals (n=20) and one group of maxillary and mandibular canines (n=20) were instrumented and obturated by cold lateral compaction using AH 26 as the seater. The fitted roots were bucco-Lingually and mesio-distatty radiographed. Using a scoring system, the quality of each root fitting was radiographically evaluated, the higher the score the poorer the quality. Fluid transport along the root filling was then measured using a fluid transportation device. Each root was horizontally sectioned 4 and 6 mm from the apex. Images of the cross-sections were taken, using a microscope and a digital camera. Images were scanned into a PC as TIFF images. Using a KS 100 Imaging system the canal area and the gutta-percha fitted areas were measured. The percentage of gutta-percha fitted areas was calculated. Results: Considering the radiographic scores of the two different projections together the score was significantly higher for the mandibular incisors than for the canines (P=0.039). The radiographic score was significantly higher for the mesiodistal radiograph in comparison with the bucco-lingual radiograph (P=0.0001), for the canines as well as the incisors. Using only the bucco-lingual radiograph there was no significant difference between the mandibular incisors and the canines (P=0.992). The mandibular incisors displayed significantly more fluid transport than the canines (P=0.049). A significantly greater percentage of gutta-percha fitted areas was found in the cross-sections of canines as compared to the cross-sections of mandibular incisors (P=0.000001). The correlation between the radiographic score of the mesio-distal radiograph and the PGP 4 and 6 mm was significant (P=0.013). There was no significant correlation between the FT and the radiograph or the FT and the PGP. Conclusions: The quality of the root fillings in oval canal- mandibular incisors may be compromised. (c) 2005 Published by Elsevier Ltd.
引用
收藏
页码:683 / 688
页数:6
相关论文
共 27 条
[1]   INVESTIGATION OF THE CANAL SPACE OCCUPIED BY GUTTA-PERCHA FOLLOWING LATERAL CONDENSATION AND THERMOMECHANICAL CONDENSATION [J].
BEER, R ;
GANGLER, P ;
RUPPRECHT, B .
INTERNATIONAL ENDODONTIC JOURNAL, 1987, 20 (06) :271-275
[2]   RADIOGRAPHIC VOIDS AND LEAKAGE ALONG ROOT FILLINGS INVITRO [J].
BEYEROLSEN, EM ;
ORSTAVIK, D ;
ERIKSEN, HM .
INTERNATIONAL ENDODONTIC JOURNAL, 1983, 16 (02) :51-58
[3]  
DAHLEN G, 1992, CONT ORAL MICROBIOLO, P444
[4]   MICROLEAKAGE MEASUREMENT OF SELECTED RESTORATIVE MATERIALS - A NEW INVITRO METHOD [J].
DERKSON, GD ;
PASHLEY, DH ;
DERKSON, ME .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 56 (04) :435-440
[5]   A LABORATORY STUDY OF ROOT FILLINGS IN TEETH OBTURATED BY LATERAL CONDENSATION OF GUTTA-PERCHA OR THERMAFIL OBTURATORS [J].
DUMMER, PMH ;
LYLE, L ;
RAWLE, J ;
KENNEDY, JK .
INTERNATIONAL ENDODONTIC JOURNAL, 1994, 27 (01) :32-38
[6]   AN INVITRO STUDY OF THE QUALITY OF ROOT FILLINGS IN TEETH OBTURATED BY LATERAL CONDENSATION OF GUTTA-PERCHA OR THERMAFIL OBTURATORS [J].
DUMMER, PMH ;
KELLY, T ;
MEGHJI, A ;
SHEIKH, I ;
VANITCHAI, JT .
INTERNATIONAL ENDODONTIC JOURNAL, 1993, 26 (02) :99-105
[7]  
Eckerbom M, 1997, ENDOD DENT TRAUMATOL, V13, P259
[8]   A COMPARISON OF THE AREA OF THE CANAL SPACE OCCUPIED BY GUTTA-PERCHA FOLLOWING 4 GUTTA-PERCHA OBTURATION TECHNIQUES USING PROCOSOL SEALER [J].
EGUCHI, DS ;
PETERS, DD ;
HOLLINGER, JO ;
LORTON, L .
JOURNAL OF ENDODONTICS, 1985, 11 (04) :166-175
[9]   AN INVITRO COMPARISON OF THE EFFICACY OF THE STEPBACK TECHNIQUE VERSUS A STEP-BACK ULTRASONIC TECHNIQUE IN HUMAN MANDIBULAR MOLARS [J].
GOODMAN, A ;
READER, AI ;
BECK, M ;
MELFI, R ;
MEYERS, W .
JOURNAL OF ENDODONTICS, 1985, 11 (06) :249-256
[10]   A comparative study of root canal preparation with HERO 642 and Quantec SC rotary Ni-Ti instruments [J].
Hülsmann, M ;
Schade, M ;
Schäfers, F .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (07) :538-546