A comparative study of root canal preparation with HERO 642 and Quantec SC rotary Ni-Ti instruments

被引:70
作者
Hülsmann, M [1 ]
Schade, M [1 ]
Schäfers, F [1 ]
机构
[1] Univ Gottingen, Zentrum ZMK, Dept Operat Dent, D-37075 Gottingen, Germany
关键词
automated root canal preparation; HERO; 642; Ni-Ti instruments; Quantec SC;
D O I
10.1046/j.1365-2591.2001.00431.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The purpose of this study was to compare several parameters of root canal preparation using two different rotary nickel-titanium instruments: HERO 642 (MicroMega, Besancon, France) and Quantec SC (Tycom, Irvine, CA, USA). Methodology Fifty extracted mandibular molars with root canal curvatures between 20 degrees and 40 degrees were imbedded into a muffle system. All root canals were prepared to size 45 (Quantec SC), or 40 (HERO 642), respectively. The following parameters were evaluated: straightening of curved root canals, postoperative root canal diameter, safety issues (file fractures, perforations, apical blockages, loss of working length), cleaning ability, and working time. Results Both Ni-Ti-systems maintained curvature well: the mean degree of straightening was 2.3 degrees for Quantec SC and 1.6 degrees for HERO 642. Most procedural incidents occurred with Quantec SC instruments (five fractures, three apical blockages, eight cases of loss of working length), HERO 642 preparation resulted in three blockages and one perforation. Following preparation with HERO 642, 63% of the root canals showed a round, 24% an oval, and 17% an irregular diameter; Quantec SC preparations resulted in a round diameter in 24% of the cases, oval shape in 29%, and irregular cross-section in 47% of the cases. Mean working time was shorter for HERO 642 (52 s) than for Quantec (117 s). Cleanliness of the root canal walls was investigated under the SEM using a five-score system for debris and smear layer. For debris HERO 642 achieved better results (80% scores 1 and 2) than Quantec SC (76%). The results for smear layer were similar: cleaner root canal walls were found after preparation with HERO 642 (53% scores 1 and 2), followed by Quantec SC (41%). Conclusions Both systems respected original root canal curvature well and showed good cleaning ability; Quantec SC showed deficiencies in terms of safety.
引用
收藏
页码:538 / 546
页数:9
相关论文
共 52 条
[1]   THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL [J].
ABOURASS, M ;
FRANK, AL ;
GLICK, DH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) :792-794
[2]  
ALOMARI MAO, 1992, INT ENDOD J, V25, P57, DOI 10.1111/j.1365-2591.1992.tb00738.x
[3]  
ALOMARI MAO, 1992, INT ENDOD J, V21, P67
[4]  
*AM ASS END, 1994, CONT TERM END
[5]   The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses [J].
Barbakow, F ;
Lutz, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :46-50
[6]  
BARTHEL CR, 1998, J ENDODONT, V24, P293
[7]   Effect of experience on quality of canal preparation with rotary nickel-titanium files [J].
Baumann, MA ;
Roth, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (06) :714-718
[8]   The removal of the smear layer using the Quantec system.: A study using the scanning electron microscope [J].
Bertrand, MF ;
Pizzardini, P ;
Muller, M ;
Médioni, E ;
Rocca, JP .
INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (03) :217-224
[9]  
BERTRAND MF, 1999, J DENT RES, V78, P397
[10]  
Bolanos OR, 1988, J ENDODONT, V8, P392