Day-to-day variability in acid reflux patterns using the BRAVO pH monitoring system

被引:64
作者
Ahlawat, SK [1 ]
Novak, DJ [1 ]
Williams, DC [1 ]
Maher, KA [1 ]
Barton, F [1 ]
Benjamin, SB [1 ]
机构
[1] Georgetown Univ Hosp, Div Gastroenterol, Dept Med, Washington, DC 20007 USA
关键词
gastroesophageal reflux; wireless pH monitoring; esophageal pH monitoring;
D O I
10.1097/01.mcg.0000190753.25750.0e
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Goals: The wireless pH monitoring system such as the BRAVO pH system is a significant advancement in the evaluation of patients with gastroesophageal reflux because of its potentially better tolerability and the ability to record data over a 48-hour period. The aim of our study was to evaluate safety, performance, tolerability, and day-to-day variability in acid reflux patterns using the BRAVO pH system. Methods: A total of 90 consecutive patients (48 men and 42 women) with persistent reflux symptoms underwent BRAVO pH capsule placement from October 2002 to August 2003 at a tertiary care hospital. The BRAVO pH capsule was deployed 6 cm proximal to the squamocolumnar junction under endoscopic guidance. The pH recordings over 48 hours were obtained after uploading data to a computer from the pager-like device that recorded pH signals from the BRAVO pH capsule. Results: Successful pH data over 48 hours was obtained in 90% of patients. Nearly two thirds of patients experienced a variety of symptoms ranging from a foreign body sensation to chest discomfort or pain. Four patients had severe chest pain, 3 of whom required endoscopic removal of the BRAVO pH capsule. In 74.4% of patients, number of reflux events as well as time (%) pH < 4 correlated from the first 24-hour period to the second 24-hour period. However, in 28% of patients, no predictable pattern of (%) time pH < 4 in the supine position was reproduced from one 24-hour period to the next 24-hour period. Conclusions: The BRAVO pH system appears a safe and effective method of recording esophageal acid exposure. It is an acceptable alternative for patients who are unwilling or unable to tolerate nasopharyngeal catheter-based pH studies, and it has a potential advantage of the 2-day recording period.
引用
收藏
页码:20 / 24
页数:5
相关论文
共 12 条
[1]  
ANGGIANSAH A, 1993, AM J GASTROENTEROL, V88, P842
[2]  
ANTONIAZZI L, 2002, DIGESTIVE DIS W 0519
[3]   CHEST PAIN AS A CONSEQUENCE OF ABNORMAL VISCERAL NOCICEPTION [J].
CANNON, RO ;
BENJAMIN, SB .
DIGESTIVE DISEASES AND SCIENCES, 1993, 38 (02) :193-196
[4]   Reliability of 24-hour oesophageal pH monitoring under standardized conditions [J].
Franzén, T ;
Grahn, LT .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2002, 37 (01) :6-8
[5]   IRRITABLE ESOPHAGUS [J].
JANSSENS, JPF ;
VANTRAPPEN, G .
AMERICAN JOURNAL OF MEDICINE, 1992, 92 :S27-S32
[6]   REPRODUCIBILITY OF AMBULATORY ESOPHAGEAL PH MONITORING [J].
JOHNSSON, F ;
JOELSSON, B .
GUT, 1988, 29 (07) :886-889
[7]   Clinical esophageal pH recording: A technical review for practice guideline development [J].
Kahrilas, PJ ;
Quigley, EMM .
GASTROENTEROLOGY, 1996, 110 (06) :1982-1996
[8]  
OURS T, 2002, DIGESTIVE DIS W 0519
[9]   Ambulatory esophageal pH monitoring using a wireless system [J].
Pandolfino, JE ;
Richter, JE ;
Ours, T ;
Guardino, JM ;
Chapman, J ;
Kahrilas, PJ .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (04) :740-749
[10]  
Streets CG, 2001, GASTROENTEROLOGY, V120, pA35