On the measurement technique for specific absorption rate of nanoparticles in an alternating electromagnetic field

被引:58
作者
Huang, S. [1 ]
Wang, S-Y [1 ]
Gupta, A. [2 ]
Borca-Tasciuc, D-A [1 ]
Salon, S. J. [3 ]
机构
[1] Rensselaer Polytech Inst, Dept Mech Aerosp & Nucl Engn, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Dept Chem & Biol Engn, Troy, NY 12180 USA
[3] Rensselaer Polytech Inst, Dept Elect Comp & Syst Engn, Troy, NY 12180 USA
基金
美国国家科学基金会;
关键词
specific absorption rate (SAR); thermal power; magnetic nanoparticles; magnetic fluids; hyperthermia; MAGNETIC FLUID; HYPERTHERMIA; THERAPY; PARTICLES;
D O I
10.1088/0957-0233/23/3/035701
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Accurate measurement of specific absorption rate (SAR) is essential for quantifying the power dissipation of magnetic nanoparticle suspensions in alternating magnetic fields, which have applications in cancer hyperthermia. Current SAR measurement setups usually comprise a coil surrounding a container holding the sample fluid. The temperature rise of the magnetic fluid is recorded once the field is turned on and SAR is determined from the initial slope of the temperature as a function of time. However several factors, including volume of the fluid sample, thermal properties of the container, positioning of the temperature sensor and non-uniformities in the magnetic field induced by the sample and coil geometry, may influence the reported SAR. To illustrate these effects theoretical and experimental investigations are carried out. The results show that the SAR measured on samples of relatively small volume may be subjected to errors associated with conductive heat losses to the container holding the sample. Numerical simulations also show that the fluid experiences internal convection during heating, which dictates the positioning of the temperature sensor. Moreover, the heat generation is shown to depend on sample geometry because this has an effect on the magnetic flux passing through the sample. Since SAR is proportional to squared field strength, small differences in the magnetic field may result in large differences in SAR. The findings reported here are also relevant to the measurement of power dissipation in capacitively coupled, radio-frequency heating of metallic nanoparticles.
引用
收藏
页数:6
相关论文
共 15 条
[1]  
[Anonymous], COLL PHYS
[2]   Magnetic particle hyperthermia:: nanoparticle magnetism and materials development for cancer therapy [J].
Hergt, Rudolf ;
Dutz, Silvio ;
Mueller, Robert ;
Zeisberger, Matthias .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2006, 18 (38) :S2919-S2934
[3]  
Janna W.S., 2000, Engineering Heat Transfer
[4]   Biocompatible high-moment FeCo-Au magnetic nanoparticles for magnetic hyperthermia treatment optimization [J].
Kline, Timothy L. ;
Xu, Yun-Hao ;
Jing, Ying ;
Wang, Jian-Ping .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2009, 321 (10) :1525-1528
[5]   Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy [J].
Krishnan, Kannan M. .
IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (07) :2523-2558
[6]   Integrated genetic analysis microsystems [J].
Lagally, ET ;
Mathies, RA .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2004, 37 (23) :R245-R261
[7]   Size dependence of specific power absorption of Fe3O4 particles in AC magnetic field [J].
Ma, M ;
Wu, Y ;
Zhou, H ;
Sun, YK ;
Zhang, Y ;
Gu, N .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 268 (1-2) :33-39
[8]   Magnetic nanoparticle design for medical diagnosis and therapy [J].
Mornet, S ;
Vasseur, S ;
Grasset, F ;
Duguet, E .
JOURNAL OF MATERIALS CHEMISTRY, 2004, 14 (14) :2161-2175
[9]   Heating ability of magnetite nanobeads with various sizes for magnetic hyperthermia at 120 kHz, a noninvasive frequency [J].
Okawa, K. ;
Sekine, M. ;
Maeda, M. ;
Tada, M. ;
Abe, M. ;
Matsushita, N. ;
Nishio, K. ;
Handa, H. .
JOURNAL OF APPLIED PHYSICS, 2006, 99 (08)
[10]   Heating magnetic fluid with alternating magnetic field [J].
Rosensweig, RE .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2002, 252 (1-3) :370-374