Tantalum Augments for Paprosky IIIA Defects Remain Stable at Midterm Followup

被引:98
作者
Del Gaizo, Daniel J. [1 ,2 ]
Kancherla, Vamsi [1 ,2 ]
Sporer, Scott M. [1 ,2 ]
Paprosky, Wayne G. [1 ,2 ]
机构
[1] Cent Dupage Hosp, Winfield, IL 60190 USA
[2] Rush Univ, Dept Orthoped Surg, Med Ctr, Chicago, IL 60612 USA
关键词
TOTAL HIP-ARTHROPLASTY; METAL ACETABULAR COMPONENT; PELVIC DISCONTINUITY; BONE LOSS; REVISION; ALLOGRAFTS; RECONSTRUCTION;
D O I
10.1007/s11999-011-2170-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Initial reports with short-term followup of porous tantalum acetabular components and augments for Paprosky IIIA acetabular defects demonstrate high hip scores, low rates of aseptic loosening, and low rates of complications. However, longer-term followup with a larger cohort is needed to determine the durability of these reconstructions. We therefore determined the functional scores, rates of aseptic loosening, and complications in patients with Paprosky IIIA acetabular defects treated with porous tantalum acetabular components and augments. We retrospectively reviewed 37 acetabular revisions in 36 patients (one patient with bilateral revisions) treated with a porous tantalum acetabular component and augment. All patients had defects classified as Type IIIa using the system of Paprosky et al. Harris hip scores were obtained and radiographic examination was performed before surgery and through most recent followup. The minimum followup was 26 months (mean, 60 months; range, 26-106 months). One patient developed aseptic loosening of the acetabular reconstruction requiring revision; seven other patients required further surgery for periprosthetic femoral fracture (two), acute infection (three), and recurrent dislocation (two). Thirty-five of 37 hips had no or occasional pain at final followup. Mean Harris hip scores improved from 33.0 preoperatively (range, 12.6-58.7) to 81.5 postoperatively (range, 27.0-99.8). Although the complication rate requiring further surgery was considerable, most patients with these reconstructions had pain relief and reasonable function with low rates of loosening at midterm followup. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 22 条
[1]
Bradford MS, 1995, SEMIN ARTHROPLASTY, V2, P76
[2]
High failure rate of a constrained acetabular liner in revision total hip arthroplasty [J].
Della Valle, CJ ;
Chang, D ;
Sporer, S ;
Berger, RA ;
Rosenberg, AG ;
Paprosky, WG .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :103-107
[3]
Emerson Jr RH, 1993, SEMIN ARTHROPLASTY, V1, P2
[4]
Management of severe bone loss in acetabular revision using a trabecular metal shell [J].
Flecher, Xavier ;
Sporer, Scott ;
Paprosky, Wayne .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :949-955
[5]
FRANZEN H, 1993, CLIN ORTHOP RELAT R, P131
[6]
Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft - Study with a minimum five-year follow-up [J].
Garbuz, D ;
Morsi, E ;
Gross, AE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05) :693-697
[7]
Revision Hip Arthroplasty Infection is the Most Common Cause of Failure [J].
Jafari, S. Mehdi ;
Coyle, Catelyn ;
Mortazavi, S. M. Javad ;
Sharkey, Peter F. ;
Parvizi, Javad .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (08) :2046-2051
[8]
Effect of femoral head size and abductors on dislocation after revision THA [J].
Kung, Peter L. ;
Ries, Michael D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :170-174
[9]
Lingaraj K, 2009, J BONE JOINT SURG BR, V91B, P1555, DOI 10.1302/0301-620X.91B12.22517
[10]
Revision total hip arthroplasty with shelf bulk allografts - A long-term follow-up study [J].
Morsi, E ;
Garbuz, D ;
Gross, AE .
JOURNAL OF ARTHROPLASTY, 1996, 11 (01) :86-90