Current distribution in polymer electrolyte membrane fuel cell with active water management

被引:53
作者
Strickland, Daniel G. [1 ]
Litster, Shawn [1 ]
Santiago, Juan G. [1 ]
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
PEM fuel cell; electroosmotic pump; segmented cell; parallel flow; water management; wick;
D O I
10.1016/j.jpowsour.2007.08.059
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Air delivery is typically the greatest parasitic power loss in polymer electrolyte membrane fuel cell (PEMFC) systems. We here present a detailed study of an active water management system for PEMFCs, which uses a hydrophilic, porous cathode flow field, and an electroosmotic (EO) pump for water removal. This active pumping of liquid water allows for stable operation with relatively low air flow rates and low air pressure and parallel cathode channel architectures. We characterize in-plane transport issues and power distributions using a three by three segmented PEMFC design. Our transient and steady state data provide insight into the dynamics and spatial distribution of flooding and flood-recovery processes. Segment-specific polarization curves reveal that the combination of a wick and an EO pump can effect a steady state, uniform current distribution for a parallel channel cathode flow field, even at low air stoichiometries (alpha(air) = 1.5). The segmented cell measurements also reveal the mechanisms and dynamics associated with EO pump based recovery from catastrophic flooding. For most operating regimes, the EO pump requires less than 1% of the fuel cell power to recover from near-catastrophic flooding, prevent flooding, and extend the current density operation range. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 281
页数:10
相关论文
共 34 条
[1]   Fuel economy of hydrogen fuel cell vehicles [J].
Ahluwalia, RK ;
Wang, X ;
Rousseau, A ;
Kumar, R .
JOURNAL OF POWER SOURCES, 2004, 130 (1-2) :192-201
[2]   Further refinements in the segmented cell approach to diagnosing performance in polymer electrolyte fuel cells [J].
Bender, G ;
Wilson, MS ;
Zawodzinski, TA .
JOURNAL OF POWER SOURCES, 2003, 123 (02) :163-171
[3]   Measurement of the current distribution along a single flow channel of a solid polymer fuel cell [J].
Brett, DJL ;
Atkins, S ;
Brandon, NP ;
Vesovic, V ;
Vasileiadis, N ;
Kucernak, AR .
ELECTROCHEMISTRY COMMUNICATIONS, 2001, 3 (11) :628-632
[4]   LOCAL MASS-TRANSPORT EFFECTS IN THE FMOI LABORATORY ELECTROLYZER [J].
BROWN, CJ ;
PLETCHER, D ;
WALSH, FC ;
HAMMOND, JK ;
ROBINSON, D .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1992, 22 (07) :613-619
[5]   Dependence of current distribution on water management in PEFC of technical size [J].
Büchi, FN ;
Geiger, AB ;
Neto, RP .
JOURNAL OF POWER SOURCES, 2005, 145 (01) :62-67
[6]   A printed circuit board approach to measuring current distribution in a fuel cell [J].
Cleghorn, SJC ;
Derouin, CR ;
Wilson, MS ;
Gottesfeld, S .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1998, 28 (07) :663-672
[7]   ELECTRODE CURRENT DISTRIBUTION IN A HYPOCHLORITE CELL [J].
CZARNETZKI, LR ;
JANSSEN, LJJ .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1989, 19 (05) :630-636
[8]   Start-up analysis for automotive PEM fuel cell systems [J].
De Francesco, M ;
Arato, E .
JOURNAL OF POWER SOURCES, 2002, 108 (1-2) :41-52
[9]   Fuel cells for portable applications [J].
Dyer, CK .
JOURNAL OF POWER SOURCES, 2002, 106 (1-2) :31-34
[10]   Current distribution mapping in polymer electrolyte fuel cells - A finite element analysis of measurement uncertainty imposed by lateral currents [J].
Eckl, R ;
Grinzinger, R ;
Lehnert, W .
JOURNAL OF POWER SOURCES, 2006, 154 (01) :171-179