Band splitting in overloaded isocratic elution chromatography I. The experimental evidence

被引:11
作者
Gritti, F
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN USA
基金
美国国家科学基金会;
关键词
band splitting; band profile; fraction collection; phenol;
D O I
10.1016/S0021-9673(03)00972-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A series of samples of increasing volume (from 0.001 to 4.0 cm(3)), containing the same constant concentration (40 g/l) of two simple compounds, ethylbenzoate and 4-tert.-butylphenol were injected on a Kromasil-C-18 column with methanol-water (62:38, v/v) as the mobile phase. Complex band profiles were observed when the volume of the sample became large enough and strong band interference took place. The analysis of the fractions collected during the elution of the mixed band demonstrates that, for samples larger than 2 cm(3), the band of 4-tert.-butylphenol is split into two separate bands, one eluted before and the other eluted after the band of ethylbenzoate. Such a phenomenon has never been observed yet in RPLC, under isocratic elution conditions. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 17 条
[1]   DISPLACEMENT OF PROTEINS IN HYDROPHOBIC INTERACTION CHROMATOGRAPHY [J].
ANTIA, FD ;
FELLEGVARI, I ;
HORVATH, C .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1995, 34 (08) :2796-2804
[2]   Comparing the optimum performance of the different modes of preparative liquid chromatography [J].
Felinger, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 796 (01) :59-74
[3]   Multicomponent interferences in overloaded gradient elution chromatography [J].
Felinger, A ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) :27-37
[4]   COMPARISON OF AN EXPERIMENTAL COMPETITIVE ISOTHERM AND THE LEVAN-VERMEULEN MODEL AND PREDICTION OF BAND PROFILES IN A CASE OF SELECTIVITY REVERSAL [J].
GOLSHANSHIRAZI, S ;
HUANG, JX ;
GUIOCHON, GA .
ANALYTICAL CHEMISTRY, 1991, 63 (11) :1147-1154
[5]   Repeatability and reproducibility of high concentration data in reversed-phase liquid chromatography I.: Overloaded band profiles on Kromasil-C18 [J].
Gritti, F ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1003 (1-2) :43-72
[6]  
GRITTI F, 2003, IN PRESS J COLLOID I
[7]   Preparative liquid chromatography [J].
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :129-161
[8]  
Guiochon G., 1994, FUNDAMENTALS PREPARA
[9]   MEASUREMENT OF ADSORPTION-ISOTHERMS BY LIQUID-CHROMATOGRAPHY [J].
JACOBSON, J ;
FRENZ, J ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :53-68
[10]   CHROMATOGRAPHIC BAND PROFILES AND BAND SEPARATION OF ENANTIOMERS AT HIGH-CONCENTRATION [J].
JACOBSON, S ;
GOLSHANSHIRAZI, S ;
GUIOCHON, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (18) :6492-6498