Noninvasive cardiac output monitoring by aortic blood flow determination:: Evaluation of the Sometec Dynemo-3000 system

被引:70
作者
Cariou, A [1 ]
Monchi, M [1 ]
Joly, LM [1 ]
Bellenfant, F [1 ]
Claessens, YE [1 ]
Thébert, D [1 ]
Brunet, F [1 ]
Dhainaut, JF [1 ]
机构
[1] Cochin Port Royal Univ Hosp, Med Intens Care Unit, F-75679 Paris 14, France
关键词
measurement techniques; cardiac output; Doppler echocardiography; Doppler ultrasound; monitoring; catheterization; pulmonary artery; aorta; hemodynamics;
D O I
10.1097/00003246-199812000-00043
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The Sometec Dynemo-3000 system allows the permanent measurement of descending aorta diameter by an echographic (A-scan) device and the blood flow velocity by a pulse Doppler velocimeter. The Dynemo-3000 then furnishes a new hemodynamic parameter, i.e., desceding aortic blood flow (ABF), which is a fraction of the cardiac output (CO). We evaluate the ability of this system to measure the aortic diameter and to accurately detect ABF changes. Design: A case study prospective trial. Setting: A 24-bed medical intensive care unit of a 1,100-bed university hospital. Patients: Twenty critically ill patients fully sedated, mechanically ventilated, and monitored by a pulmonary artery catheter. Interventions: CO values determined by conventional thermodilution method (TD-CO) and ABF were recorded during the study, which included two initial baseline periods, a dobutamine infusion (5 mu g/kg/min) interval of 30 mins, and a third baseline period. To assess the accuracy of A-scan, aortic diameter was measured by transesophageal echocardiography. The difference between echocardiography and A scan was used to determine bias and precision for aortic diameter measurements. TD-CO and ABF variations were analyzed using Kruskal-Wallis and Wilcoxon tests. Association between TD-CO and ABF values was determined by calculating the linear correlation coefficient. The ability of ABF to detect a TD-CO >6.0 L/min and its variations >13% was analyzed by determination of sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values. Measurements and Main Results: Aortic diameter measurements by A scan and bidimensional methods were 23.0 +/- 2.8 mm (SD) and 24.2 +/- 2.7 mm, respectively. Bias and precision were 1.1 mm and 1.4 mm (95% confidence interval: -1.9 to 3.7), respectively. During the course of dobutamine infusion, we observed a significant increase of TD-CO mean value from 6.65 +/- 1.53 L/min to 9.30 +/- 2.5 L/min (p = .0008), and a parallel and significant increase in ABF mean value from 4.34 +/- 1.18 L/min to 5.70 +/- 1.63 L/min (p = .0029). Absolute TD-CO and ABF values had a correlation coefficient of 0.80. For detection of an increased TD-CO, PPV and NPV were 87% and 86%, respectively. For detection of TD-CO changes >13%, PPV and NPV were 80% and 94%, respectively. Conclusions: The Dynemo-3000 system is able to display the real aortic diameter, which is one of the most important components of this noninvasive ultrasonic technique. When compared with TD-CO, the ABF determination provided by this ultrasonic device constitutes a reliable noninvasive tool for estimating CO and tracking its changes.
引用
收藏
页码:2066 / 2072
页数:7
相关论文
共 20 条
  • [1] NONINVASIVE CARDIAC-OUTPUT, DOPPLER FLOWMETRY, AND GOLD-PLATED ASSUMPTIONS
    BERNSTEIN, DP
    [J]. CRITICAL CARE MEDICINE, 1987, 15 (09) : 886 - 888
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] CATHIGNOL D, 1985, Annales Francaises d'Anesthesie et de Reanimation, V4, P438, DOI 10.1016/S0750-7658(85)80279-3
  • [4] NONINVASIVE CONTINUOUS HEMODYNAMIC AND PETCO(2) MONITORING DURING PEROPERATIVE CARDIAC-ARREST
    GUEUGNIAUD, PY
    MUCHADA, R
    BERTINMAGHIT, M
    GRIFFITH, N
    PETIT, P
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (10): : 910 - 913
  • [5] GUEUGNIAUD PY, 1993, REAN URG, V2, P533
  • [6] CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT DURING AORTIC CROSS-CLAMPING BY THE ESOPHAGEAL DOPPLER MONITOR ODM-1
    KLOTZ, KF
    KLINGSIEK, S
    SINGER, M
    WENK, H
    ELEFTHERIADIS, S
    KUPPE, H
    SCHMUCKER, P
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 (06) : 655 - 660
  • [7] PROGNOSIS IN ACUTE ORGAN-SYSTEM FAILURE
    KNAUS, WA
    DRAPER, EA
    WAGNER, DP
    ZIMMERMAN, JE
    [J]. ANNALS OF SURGERY, 1985, 202 (06) : 685 - 693
  • [8] NONINVASIVE AORTIC BLOOD-FLOW MEASUREMENT USING AN INTRAESOPHAGEAL PROBE
    LAVANDIER, B
    CATHIGNOL, D
    MUCHADA, R
    XUAN, BB
    MOTIN, J
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03) : 451 - 460
  • [9] ASSESSMENT OF A POTENTIALLY NONINVASIVE METHOD FOR MONITORING AORTIC BLOOD-FLOW IN CHILDREN
    LAVANDIER, B
    MUCHADA, R
    CHIGNIER, E
    FADY, JF
    BIRER, A
    CATHIGNOL, D
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) : 107 - 116
  • [10] A NEW SIMPLIFIED ACUTE PHYSIOLOGY SCORE (SAPS-II) BASED ON A EUROPEAN NORTH-AMERICAN MULTICENTER STUDY
    LEGALL, JR
    LEMESHOW, S
    SAULNIER, F
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (24): : 2957 - 2963