Accounting for erroneous electrode data in electrical impedance tomography

被引:24
作者
Adler, A [1 ]
机构
[1] Univ Ottawa, Sch Informat Technol & Engn, Ottawa, ON K1N 6N5, Canada
关键词
electrical impedance tomography; image reconstruction; electrodes;
D O I
10.1088/0967-3334/25/1/028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An unfortunate occurrence in experimental measurements with electrical impedance tomography is electrodes which become detached or poorly connected, such that the measured data cannot be used. This paper develops an image reconstruction methodology which allows use of the remaining valid data. A finite element model of the EIT difference imaging forward problem is linearized as z = Hx, where z represents the change in measurements and x the element log conductivity changes. Image reconstruction is represented in terms of a maximum a posteriori (MAP) estimate as x = inv(H(t)inv (R-n) + inv (R-x)) H(t)inv (R-n) z, where R-x and R-n represent the a priori estimates of image and measurement noise crosscorrelations, respectively. Using this formulation, missing electrode data can be naturally modelled as infinite noise on all measurements using the affected electrodes. Simulations indicate position error and resolution are close (+/-10%) to the values calculated without missing electrode data as long as the target was further than 10% of the medium diameter from the affected electrode. Applications of this technique to experimental data show good results in terms of removing artefacts from images.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 15 条
[1]   Impedance imaging of lung ventilation: Do we need to account for chest expansion? [J].
Adler, A ;
Guardo, R ;
Berthiaume, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (04) :414-420
[2]   Monitoring changes in lung air and liquid volumes with electrical impedance tomography [J].
Adler, A ;
Amyot, R ;
Guardo, R ;
Bates, JHT ;
Berthiaume, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) :1762-1767
[3]   Electrical impedance tomography: Regularized imaging and contrast detection [J].
Adler, A ;
Guardo, R .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (02) :170-179
[4]   Patient-instrument connection errors in bioelectrical impedance measurement [J].
Al-Hatib, F .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) :285-296
[5]   ACT3 - A HIGH-SPEED, HIGH-PRECISION ELECTRICAL-IMPEDANCE TOMOGRAPH [J].
COOK, RD ;
SAULNIER, GJ ;
GISSER, DG ;
GOBLE, JC ;
NEWELL, JC ;
ISAACSON, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (08) :713-722
[6]   Propagation of measurement noise through backprojection reconstruction in electrical impedance tomography [J].
Frangi, AF ;
Riu, PJ ;
Rosell, J ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (06) :566-578
[8]   AN EXPERIMENTAL-STUDY IN ELECTRICAL-IMPEDANCE TOMOGRAPHY USING BACKPROJECTION RECONSTRUCTION [J].
GUARDO, R ;
BOULAY, C ;
MURRAY, B ;
BERTRAND, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (07) :617-627
[9]   Movement artefact rejection in impedance pneumography using six strategically placed electrodes [J].
Khambete, ND ;
Brown, BH ;
Smallwood, RH .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) :79-88
[10]   ERRORS IN PROLONGED ELECTRICAL-IMPEDANCE MEASUREMENTS DUE TO ELECTRODE REPOSITIONING AND POSTURAL CHANGES [J].
LOZANO, A ;
ROSELL, J ;
PALLASARENY, R .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 (02) :121-130