摘要
PET/CT imaging modalities have been shown to be useful in the diagnosis, staging, and monitoring of malignant diseases. Its inclusion into the treatment planning process is now central to modern radiotherapy practice. However, it is essential to be cognisant of the factors that are necessary in order to ensure that the acquired images are consistent with the requirements for both treatment planning and treatment delivery. Essential parameters required in image acquisition for radiotherapy planning and treatment include consistencies of table tops and the use of laser light for patient set-up. But they also include the accurate definition of the patient's initial positioning and the use of proper immobilization devices in the radiotherapy department. While determining this optimum set-up, patient psychological factors and limitations that may be due to the subsequent use of PET/CT for planning purposes need to be taken into account. Furthermore, patient set-up data need to be properly recorded and transmitted to the imaging departments. To ensure the consistency of patient set-up, the radiation therapist should ideally be directly involved in informing and positioning the patient on the PET/CT. However, a proper exchange of patient-related information can also be achieved by a close liaison between the two departments and by the use of clear detailed protocols per type of patient set-up and/or per localization of tumour site. (C) 2010 European Society for Therapeutic Radiology and Oncology and European Association of Nuclear Medicine. Published by Elsevier Ireland Ltd. All rights reserved. 96 (2010) 298-301
引用
收藏
页码:298 / 301
页数:4
相关论文
共 28 条
[1]   Comparison of two dead and neck immobilization systems [J].
Bentel, GC ;
Marks, LB ;
Hendren, K ;
Brizel, DM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04) :867-873
[2]   A CUSTOMIZED HEAD AND NECK SUPPORT SYSTEM [J].
BENTEL, GC ;
MARKS, LB ;
SHEROUSE, GW ;
SPENCER, DP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (01) :245-248
[3]   Profile of European radiotherapy departments contributing to the EORTC Radiation Oncology Group (ROG) in the 21st century [J].
Budiharto, Tom ;
Musat, Elena ;
Poortmans, Philip ;
Hurkmans, Coen ;
Monti, Angelo ;
Bar-Deroma, Raquel ;
Bernstein, Zvi ;
van Tienhoven, Geertjan ;
Collette, Laurence ;
Duclos, Frederic ;
Davis, Bernard ;
Aird, Edwin .
RADIOTHERAPY AND ONCOLOGY, 2008, 88 (03) :403-410
[4]   18F-FDG PET/CT for Image-Guided and Intensity-Modulated Radiotherapy [J].
Ford, Eric C. ;
Herman, Joseph ;
Yorke, Ellen ;
Wahl, Richard L. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (10) :1655-1665
[5]   Is there any future in radiotherapy planning without the use of PET: unraveling the myth... [J].
Gregoire, V .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 (03) :261-263
[6]   The rise of cultural identities in the Lower Palaeolithic: the case of Italy. [J].
Grifoni, Renata ;
Tozzi, Carlo .
COMPTES RENDUS PALEVOL, 2006, 5 (1-2) :137-148
[7]   Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy [J].
Guckenberger, Matthias ;
Krieger, Thomas ;
Richter, Anne ;
Baier, Kurt ;
Wilbert, Juergen ;
Sweeney, Reinhart A. ;
Flentje, Michael .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :288-295
[8]   A comparison of two immobilization systems for stereotactic body radiation therapy of lung tumors [J].
Han, Kathy ;
Cheung, Patrick ;
Basran, Parminder S. ;
Poon, Ian ;
Yeung, Latifa ;
Lochray, Fiona .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (01) :103-108
[9]   Assuring high quality treatment delivery in clinical trials - Results from the Trans-Tasman Radiation Oncology Group (TROG) study 03.04 "RADAR" set-up accuracy study [J].
Haworth, Annette ;
Kearvell, Rachel ;
Greer, Peter B. ;
Hooton, Ben ;
Denham, James W. ;
Lamb, David ;
Duchesne, Gillian ;
Murray, Judy ;
Joseph, David .
RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) :299-306
[10]   Set-up verification using portal imaging; review of current clinical practice [J].
Hurkmans, CW ;
Remeijer, P ;
Lebesque, JV ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :105-120