Comparison of two dead and neck immobilization systems

被引:59
作者
Bentel, GC [1 ]
Marks, LB [1 ]
Hendren, K [1 ]
Brizel, DM [1 ]
机构
[1] DUKE UNIV,MED CTR,DEPT RADIAT ONCOL,DURHAM,NC 27710
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 38卷 / 04期
关键词
brain irradiation; head and neck irradiation; immobilization; devices; accuracy; setup; mask; cradle; thermoplastics;
D O I
10.1016/S0360-3016(97)00075-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Accurate and reproducible patient positioning is fundamental to the success of fractionated radiotherapy. Concurrent with the introduction of three-dimensional treatment planning capabilities at our institution, a head and neck immobilization system consisting of a standard foam rubber head support and three casting strips was replaced by a customized mask-based device, This study was performed to analyze the impact of the customized immobilization system on the reproducibility of patient setup during irradiation of head and neck and brain tumors. Methods and Materials: Patients treated from 1989-1991 were immobilized with the strip system while those treated from 1991-1995 were immobilized with the mask. All treatment fields were simulated and were treated on a 4 MV (where the strip, but not the mask, system was fixed to the treatment couch) or greater than or equal to 6 MV (where both the strip and the mask systems were fixed to the couch) accelerator. Port films were taken on the initial treatment day, routinely during treatment, and following shifts (requested). The number, magnitude, and direction of any isocenter shifts were retrospectively reviewed. A two-tailed chi square test was used to compare the differences in requested shifts in the strip and mask groups. Results: The study population consisted of 69 brain tumor (35 strip, 34 mask) and 71 head and neck (37 strip, 34 mask) patients. A total of 1575 port films representing 1070 isocenter placements were analyzed. No differences between the immobilization systems was seen on the 4-MV accelerator (where the mask system was not fixed to the couch). On the greater than or equal to 6-MV units, the frequency of shifts was 16.1% versus 6.2% (p = 0.002) with the strips and mask, respectively. Almost all of the benefit was seen in the routine films, where the corresponding rates were 13.2% and 4.1% (p = 0.007). For the mask system, the rate of requested shifts on routine films was 4.1% (8/197) for the greater than or equal to 6-MV units and 14.5% (24/166) for the 4-MV unit (p = 0.001). Conclusion: Using the frequency of physician-requested isocenter shifts as an indicator of the accuracy of patient repositioning, the newer mask system appears to be an improvement over the previously used strip system, provided that the immobilization device is secured to the treatment couch. Increased accuracy of daily setup provides an opportunity to improve the therapeutic ratio both by increased likelihood of tumor control and decreased risk of normal tissue complications. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:867 / 873
页数:7
相关论文
共 15 条
[1]   PATIENT IMMOBILIZATION WITH A LOW-TEMPERATURE SPLINT-BRACE MATERIAL [J].
BARISH, RJ ;
LERCH, IA .
RADIOLOGY, 1978, 127 (02) :548-548
[2]   THE EFFECTIVENESS OF IMMOBILIZATION DURING PROSTATE IRRADIATION [J].
BENTEL, GC ;
MARKS, LB ;
SHEROUSE, GW ;
SPENCER, DP ;
ANSCHER, MS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :143-148
[3]   A CUSTOMIZED HEAD AND NECK SUPPORT SYSTEM [J].
BENTEL, GC ;
MARKS, LB ;
SHEROUSE, GW ;
SPENCER, DP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (01) :245-248
[4]   PLASTIC MOLDS FOR PATIENT IMMOBILIZATION [J].
DEVEREUX, C ;
GRUNDY, G ;
LITTMAN, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1976, 1 (5-6) :553-557
[5]   THE USE OF THERMAL PLASTICS FOR IMMOBILIZATION OF PATIENTS DURING RADIOTHERAPY [J].
GERBER, RL ;
MARKS, JE ;
PURDY, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (08) :1461-1462
[6]   SIMPLE BUT SOPHISTICATED IMMOBILIZATION CASTS [J].
GOLDSON, AL ;
HENSCHKE, UK ;
ESPINOZA, MC ;
YOUNG, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (11-1) :1105-1106
[7]   PATIENT POSITIONING DEVICE FOR EXTERNAL-BEAM RADIATION-THERAPY OF HEAD AND NECK [J].
HAUSKINS, LA ;
THOMPSON, RW .
RADIOLOGY, 1973, 106 (03) :706-706
[8]   A RADIOLUCENT BITE-BLOCK APPARATUS [J].
JONES, D ;
HAFERMANN, MD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (01) :129-132
[9]   LIGHTCAST - AID TO PLANNING, TREATMENT AND IMMOBILIZATION IN RADIOTHERAPY AND RESEARCH [J].
LEWINSKY, BS ;
WALTON, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1976, 1 (9-10) :1011-1015
[10]   IMPROVING AGREEMENT BETWEEN RADIATION-DELINEATED FIELD EDGES ON SIMULATION AND PORTAL FILMS - THE EDGE TOLERANCE-TEST TOOL [J].
MCCULLOUGH, EC ;
MCCOLLOUGH, KP ;
SIMON, SP .
MEDICAL PHYSICS, 1993, 20 (02) :375-376