Optical biosensors

被引:786
作者
Borisov, Sergey M. [1 ]
Wolfbeis, Otto S. [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
D O I
10.1021/cr068105t
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Intensity, decay time, anisotropy, quenching efficiency, luminescence energy transfer, are the parameters being measured in such sensors. Chemical sensors and biosensors do not have separation capabilities unless partnered to respective additional devices. The biosensors can be divided into two kinds of groups, namely, biosensors of the catalytic type and biosensors of the affinity type. There are two main types of optical biosensors, the first exploits any changes that can occur in the intrinsic optical property of the biomolecule as a result of its interaction with the target analyte, and the second type is making use of optical labels and probes of various kinds. Optical biosensors requires a variety of scientists to cooperate in order to end up with a viable biosensor scheme, and ideally, commercial products.
引用
收藏
页码:423 / 461
页数:39
相关论文
共 411 条
  • [1] PEROXIDE OPTRODE BASED ON MICELLAR-MEDIATED CHEMI-LUMINESCENCE REACTION OF LUMINOL
    ABDELLATIF, MS
    GUILBAULT, GG
    [J]. ANALYTICA CHIMICA ACTA, 1989, 221 (01) : 11 - 17
  • [2] Fiber-optic evanescent wave biosensor for the detection of oligonucleotides
    Abel, AP
    Weller, MG
    Duveneck, GL
    Ehrat, M
    Widmer, HM
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (17) : 2905 - 2912
  • [3] Development of a microfluidic device for detection of pathogens in oral samples using upconverting phosphor technology (UPT)
    Abrams, William R.
    Barber, Cheryl A.
    McCann, Kurt
    Tong, Gary
    Chen, Zongyuan
    Mauk, Michael G.
    Wang, Jing
    Volkov, Alex
    Bourdelle, Pete
    Corstjensd, Paul L. A. M.
    Zuiderwijk, Michel
    Kardos, Keith
    Li, Shang
    Tanke, Hans J.
    Niedbala, R. Sam
    Malamud, Daniel
    Bau, Haim
    [J]. ORAL-BASED DIAGNOSTICS, 2007, 1098 : 375 - 388
  • [4] Detection of Salmonella spp. using microsphere-based, fiber-optic DNA microarrays
    Ahn, S
    Walt, DR
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (15) : 5041 - 5047
  • [5] Fiber-optic microarray for simultaneous detection of multiple harmful algal bloom species
    Ahn, Soohyoun
    Kulis, David M.
    Erdner, Deana L.
    Anderson, Donald M.
    Walt, David R.
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2006, 72 (09) : 5742 - 5749
  • [6] Optimisation of glass surfaces for optical immunosensors
    Akkoyun, A
    Bilitewski, U
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (08) : 655 - 664
  • [7] FLUORESCENCE MONITORING OF A BENZO[A]PYRENE METABOLITE USING A REGENERABLE IMMUNOCHEMICAL-BASED FIBEROPTIC SENSOR
    ALARIE, JP
    BOWYER, JR
    SEPANIAK, MJ
    HOYT, AM
    VO-DINH, T
    [J]. ANALYTICA CHIMICA ACTA, 1990, 236 (02) : 237 - 244
  • [8] ALFORD PC, 1985, J CHEM SOC P2, V5, P705
  • [9] ANDERSON FP, 1988, CLIN CHEM, V34, P1417
  • [10] Multi-analyte interrogation using the fiber optic biosensor
    Anderson, GP
    King, KD
    Gaffney, KL
    Johnson, LH
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) : 771 - 777