Immobilized diaphorase surfaces observed by scanning electrochemical microscope with shear force based tip-substrate positioning

被引:40
作者
Yamada, H [1 ]
Fukumoto, H [1 ]
Yokoyama, T [1 ]
Koike, T [1 ]
机构
[1] Natl Def Acad, Dept Appl Chem, Yokosuka, Kanagawa 2398686, Japan
关键词
D O I
10.1021/ac048582g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Imaging of a coimmobilized diaphorase and albumin surface was investigated by scanning electrochemical microscopy (SECM) with shear force based tip-substrate distance control. A microelectrode tip was attached to a commercially available tuning fork to detect the shear force between the microelectrode tip and the surface. We used the standing approach mode, which repeats an approach and retraction at each data point of the surface to obtain simultaneous current and topographic images. To check the performance of our SECM system, we imaged a platinum-patterned array electrode and a diaphorase/albumin coimmobilized glass surface. Since the system acquires current when the tip is retracted to a desired distance, this mode is useful for a relatively large microelectrode (similar to 10 mu m) and for scanning a large area (few hundreds of micrometers). Furthermore, by retracting the tip when the tip moves laterally to the next data point to avoid contact between the tip and sample surface, we successfully imaged the surface without destroying its morphology.
引用
收藏
页码:1785 / 1790
页数:6
相关论文
共 33 条
  • [21] Probing ion transfer at the liquid/liquid interface by scanning electrochemical microscopy (SECM)
    Shao, YH
    Mirkin, MV
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (49) : 9915 - 9921
  • [22] MICROFABRICATION AND CHARACTERIZATION OF DIAPHORASE-PATTERNED SURFACES BY SCANNING ELECTROCHEMICAL MICROSCOPY
    SHIKU, H
    TAKEDA, T
    YAMADA, H
    MATSUE, T
    UCHIDA, I
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (02) : 312 - 317
  • [23] Microfabrication of alkylsilanized glass substrate by electrogenerated hydroxyl radical using scanning electrochemical microscopy
    Shiku, H
    Uchida, I
    Matsue, T
    [J]. LANGMUIR, 1997, 13 (26) : 7239 - 7244
  • [24] Dual immunoassay of human chorionic gonadotropin and human placental lactogen at a miocrofabricated substrate by scanning electrochemical microscopy
    Shiku, H
    Hara, Y
    Matsue, T
    Uchida, I
    Yamauchi, T
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 438 (1-2): : 187 - 190
  • [25] Probing liquid | liquid interfaces using neutron reflection measurements and scanning electrochemical microscopy
    Strutwolf, J
    Barker, AL
    Gonsalves, M
    Caruana, DJ
    Unwin, PR
    Williams, DE
    Webster, JRP
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 483 (1-2) : 163 - 173
  • [26] Fabrication of nanometer-sized electrodes and tips for scanning electrochemical microscopy
    Sun, P
    Zhang, ZQ
    Guo, JD
    Shao, YH
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5346 - 5351
  • [27] Spatially addressed deposition and imaging of biochemically active bead microstructures by scanning electrochemical microscopy
    Wijayawardhana, CA
    Wittstock, G
    Halsall, HB
    Heineman, WR
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (02) : 333 - 338
  • [28] Wittstock G, 2001, ELECTROANAL, V13, P669, DOI 10.1002/1521-4109(200105)13:8/9<669::AID-ELAN669>3.0.CO
  • [29] 2-S
  • [30] A MICROVOLTAMMETRIC STUDY OF PERMEATION OF FERROCENE DERIVATIVES THROUGH A PLANER BILAYER LIPID-MEMBRANE
    YAMADA, H
    MATSUE, T
    UCHIDA, I
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1991, 180 (03) : 1330 - 1334