Color Doppler sonography in early renal transplantation follow-up:: Resistive index measurements versus power Doppler sonography

被引:46
作者
Trillaud, H
Merville, P
Le Linh, PT
Palussière, J
Potaux, L
Grenier, N
机构
[1] Hop Pellegrin, Serv Radiol, F-33076 Bordeaux, France
[2] Hop Pellegrin, Serv Nephrol, F-33076 Bordeaux, France
关键词
D O I
10.2214/ajr.171.6.9843297
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study was designed to compare power Doppler images of perfusion with interlobar resistive index measurements obtained during the early monitoring of renal graft transplant to diagnose cortical perfusion abnormalities and assess prognosis. SUBJECTS AND METHODS, Thirty-one patients underwent color Doppler sonography (4-7 MHz and 7-10 MHz) on day 6 +/- 2 after renal transplantation. Cortical vessel density was assessed visually and classified as either normal or decreased. Twelve months after transplantation, the results of power Doppler imaging and the levels of resistive index were reviewed in light of clinical and laboratory findings, graft biopsy results, and functional outcome. RESULTS. No significant relationship was observed among power Doppler grades, levels of resistive index, and renal function. Power Doppler grades and resistive index levels failed to allow us to distinguish between tubulopathy and rejection. However, we found a statistically significant relationship between renal function at 12 months after transplantation and power Doppler grades (p = .04). CONCLUSION. This study suggests that color Doppler sonography is insensitive in revealing and in allowing radiologists to differentiate the causes of graft dysfunction. However, power Doppler sonography allows a prediction of the functional recovery of the graft at 12 months after transplantation not provided by resistive index levels.
引用
收藏
页码:1611 / 1615
页数:5
相关论文
共 18 条
[1]  
Akiyama T, 1996, TRANSPLANT P, V28, P1458
[2]   Power Doppler sonography [J].
Bude, RO ;
Rubin, JM .
RADIOLOGY, 1996, 200 (01) :21-23
[3]   POWER VERSUS CONVENTIONAL COLOR DOPPLER SONOGRAPHY - COMPARISON IN THE DEPICTION OF NORMAL INTRARENAL VASCULATURE [J].
BUDE, RO ;
RUBIN, JM ;
ADLER, RS .
RADIOLOGY, 1994, 192 (03) :777-780
[4]   Power Doppler sonographic pattern of acute pyelonephritis in children: Comparison with CT [J].
Dacher, JN ;
Pfister, C ;
Monroc, M ;
Eurin, D ;
LeDosseur, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1451-1455
[5]   DUPLEX DOPPLER US OF RENAL-ALLOGRAFTS - CAUSES OF ELEVATED RESISTIVE INDEX [J].
DON, S ;
KOPECKY, KK ;
FILO, RS ;
LEAPMAN, SB ;
THOMALLA, JV ;
JONES, JA ;
KLATTE, EC .
RADIOLOGY, 1989, 171 (03) :709-712
[6]   VASCULAR IMAGING WITH A 3-DIMENSIONAL POWER DOPPLER SYSTEM [J].
DOWNEY, DB ;
FENSTER, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :665-668
[7]   RENAL PERFUSION - PHARMACOLOGICAL CHANGES DEPICTED WITH POWER DOPPLER US IN AN ANIMAL-MODEL [J].
DURICK, JE ;
WINTER, TC ;
SCHMIEDL, UP ;
CYR, DR ;
STARR, FL ;
MACK, LA .
RADIOLOGY, 1995, 197 (03) :615-617
[8]   DUPLEX DOPPLER SONOGRAPHY OF RENAL-TRANSPLANTS - LACK OF SENSITIVITY AND SPECIFICITY IN ESTABLISHING PATHOLOGIC DIAGNOSIS [J].
GENKINS, SM ;
SANFILIPPO, FP ;
CARROLL, BA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :535-539
[9]   DETECTION OF VASCULAR COMPLICATIONS IN RENAL-ALLOGRAFTS WITH COLOR DOPPLER FLOW IMAGING [J].
GRENIER, N ;
DOUWS, C ;
MOREL, D ;
FERRIERE, JM ;
LEGUILLOU, M ;
POTAUX, L ;
BROUSSIN, J .
RADIOLOGY, 1991, 178 (01) :217-223
[10]   Renal transplant evaluation with power Doppler sonography [J].
Hilborn, MD ;
Bude, RO ;
Murphy, KJ ;
Platt, JF ;
Rubin, JM .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :39-42