Use of personal-indoor-outdoor sulfur concentrations to estimate the infiltration factor and outdoor exposure factor for individual homes and persons

被引:117
作者
Wallace, L [1 ]
Williams, R [1 ]
机构
[1] US EPA, Natl Exposure Res Lab, Res Triangle Pk, NC 27711 USA
关键词
D O I
10.1021/es049547u
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A study of personal, indoor, and outdoor exposure to PM2.5 and associated elements has been carried out for 37 residents of the Research Triangle Park area in North Carolina. Participants were selected from persons expected to be at elevated risk from exposure to particles, and included 29 persons with hypertension and 8 cardiac patients with implanted defibrillators. Participants were monitored for 7 consecutive days in each of four seasons. One goal of the study was to estimate the contribution of outdoor PM2.5 to indoor concentrations. This depends on the infiltration factor F-inf, the fraction of outdoor PM2.5 remaining airborne after penetrating indoors. After confirming with our measurements the findings of previous studies that sulfur has few indoor sources, we estimated an average F-inf for each house based on indoor/outdoor sulfur ratios. These estimates ranged from 0.26 to 0.87, with a median value of 0.55. Since these estimates apply only to particles of size similar to that of sulfur particles (0.06-0.5 mu m diameter), and since larger particles (0.5-2.5 mu m) have lower penetration rates and higher deposition rates, these estimates are likely to be higher than the true infiltration factors for PM2.5 as a whole. In summer when air conditioners were in use, the sulfur-based infiltration factor was at its lowest (averaging 0.50) for most homes, whereas the average F-inf for the other three seasons was 0.62-0.63, Using the daily estimated infiltration factor for each house,we calculated the contribution of outdoor PM2.5 to indoor air concentrations. The indoor-gene rated contributions to indoor PM2.5 had a wider range (0-33 mu g/m(3)) than the outdoor contributions (5-22 mu g/m(3)). However, outdoor contributions exceeded the indoor-generated contributions in 27 of 36 homes. A second goal of the study was to determine the contribution of outdoor particles to personal exposure. This is determined by the "outdoor exposure factor" F-pex, the fraction of outdoor PM2.5 contributing to personal exposure. As with F-inf, we estimated F-pex by the personal/outdoor sulfur ratios. The estimates ranged from 0.33 to 0.77 with a median value of 0.53. Outdoor air particles were less important for personal exposures than for indoor concentrations, with the median outdoor contribution to personal exposure just 49%. We regressed the outdoor contributions to personal exposures on measured outdoor PM2.5 at the central site. The regressions had R-2 values ranging from 0.19 to 0.88 (median = 0.73). These values provide an indication of the extent of misclassification error in epidemiological estimates of the effect of outdoor particles on health.
引用
收藏
页码:1707 / 1714
页数:8
相关论文
共 52 条
[41]   Characterization of indoor-outdoor aerosol concentration relationships during the Fresno PM exposure studies [J].
Vette, AF ;
Rea, AW ;
Lawless, PA ;
Rodes, CE ;
Evans, G ;
Highsmith, VR ;
Sheldon, L .
AEROSOL SCIENCE AND TECHNOLOGY, 2001, 34 (01) :118-126
[42]   Correlations of personal exposure to particles with outdoor air measurements: A review of recent studies [J].
Wallace, L .
AEROSOL SCIENCE AND TECHNOLOGY, 2000, 32 (01) :15-25
[43]   Continuous monitoring of ultrafine, fine, and coarse particles in a residence for 18 months in 1999-2000 [J].
Wallace, L ;
Howard-Reed, C .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2002, 52 (07) :828-844
[44]   Effect of central fans and in-duct filters on deposition rates of ultrafine and fine particles in an occupied townhouse [J].
Wallace, LA ;
Emmerich, SJ ;
Howard-Reed, C .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (03) :405-413
[45]   Particle concentrations in inner-city homes of children with asthma: The effect of smoking, cooking, and outdoor pollution [J].
Wallace, LA ;
Mitchell, H ;
O'Connor, GT ;
Neas, L ;
Lippmann, M ;
Kattan, M ;
Koenig, J ;
Stout, JW ;
Vaughn, BJ ;
Wallace, D ;
Walter, M ;
Adams, K ;
Liu, LJS .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2003, 111 (09) :1265-1272
[46]   Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows [J].
Wallace, LA ;
Emmerich, SJ ;
Howard-Reed, C .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2002, 12 (04) :296-306
[47]   Comparison of PM2.5 and PM10 monitors [J].
Williams, R ;
Suggs, J ;
Rodes, C ;
Lawless, P ;
Zweidinger, R ;
Kwok, R ;
Creason, J ;
Sheldon, L .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (05) :497-505
[48]   Indoor, outdoor, and personal exposure monitoring of particulate air pollution: the Baltimore elderly epidemiology-exposure pilot study [J].
Williams, R ;
Creason, J ;
Zweidinger, R ;
Watts, R ;
Sheldon, L ;
Shy, C .
ATMOSPHERIC ENVIRONMENT, 2000, 34 (24) :4193-4204
[49]   The Research Triangle Park particulate matter panel study: modeling ambient source contribution to personal and residential PM mass concentrations [J].
Williams, R ;
Suggs, J ;
Rea, A ;
Sheldon, L ;
Rodes, C ;
Thornburg, J .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (38) :5365-5378
[50]   The Research Triangle Park particulate matter panel study: PM mass concentration relationships [J].
Williams, R ;
Suggs, J ;
Rea, A ;
Leovic, K ;
Vette, A ;
Croghan, C ;
Sheldon, L ;
Rodes, C ;
Thornburg, J ;
Ejire, A ;
Herbst, M ;
Sanders, W .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (38) :5349-5363