X-ray inclined lens

被引:35
作者
Hrdy, J [1 ]
机构
[1] Acad Sci Czech Republ, Inst Phys, CZ-18040 Praha 8, Czech Republic
关键词
X-ray lenses; inclined diffraction; inclined monochromators; sagittal focusing;
D O I
10.1107/S0909049598002155
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As defined here, the term 'inclined lens' means a longitudinal parabolic groove fabricated into a crystal monochromator. If properly designed, it should provide the horizontal (sagittal) focusing of an X-ray beam. The focusing is based on the sagittal deviation of the beam diffracted on the wall of the groove. This effect follows from the dynamical theory of inclined diffraction. The focusing efficiency is limited compared with other methods. On the other hand, the simplicity is the main advantage of this device. The exact shape of the groove is calculated and several methods of keeping the vertical dimension of the beam small are proposed.
引用
收藏
页码:1206 / 1210
页数:5
相关论文
共 7 条
[1]   DYNAMICAL DIFFRACTION OF X RAYS BY PERFECT CRYSTALS [J].
BATTERMAN, BW ;
COLE, H .
REVIEWS OF MODERN PHYSICS, 1964, 36 (03) :681-&
[2]  
ELLEUME P, 1997, ESRF NEWSL, V28, P33
[3]   Observation of horizontal focusing of X-rays using a toothed-crystal monochromator [J].
Hrdy, J ;
Pascarelli, S ;
D'Acapito, F ;
Colonna, S ;
Mobilio, S .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :54-56
[4]   PROPERTIES OF AN INCLINED DOUBLE CRYSTAL MONOCHROMATOR FOR SYNCHROTRON RADIATION [J].
HRDY, J ;
PACHEROVA, O .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 327 (2-3) :605-611
[5]   DOUBLE CRYSTAL MONOCHROMATOR FOR SYNCHROTRON RADIATION WITH DECREASED RADIATION POWER-DENSITY [J].
HRDY, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :459-460
[6]   A NOVEL MONOCHROMATOR FOR HIGH HEAT LOAD SYNCHROTRON X-RAY-RADIATION [J].
KHOUNSARY, AM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :461-464
[7]  
Macrander A. T., 1992, P SOC PHOTO-OPT INS, V1740, P2