Preconcentration of diazinon using multiwalled carbon nanotubes as solid-phase extraction adsorbents

被引:75
作者
Katsumata, Hideyuki [1 ]
Matsumoto, Tomohiro [1 ]
KaneCo, Satoshi. [1 ]
Suzuki, Tohru [2 ]
Ohta, Kiyohisa [1 ]
机构
[1] Mie Univ, Grad Sch Engn, Dept Chem Mat, Tsu, Mie 5148507, Japan
[2] Mie Univ, Environm Preservat Ctr, Tsu, Mie 5148507, Japan
关键词
diazinon determination; preconcentration; adsorption; multiwalled carbon nanombes; HPLC;
D O I
10.1016/j.microc.2007.10.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective column adsorption method is proposed for the preconcentration and determination of diazinon. Diazinon was preconcentrated on multiwalled carbon nanotubes (MWCNTs) as an adsorbent and then determined by high-performance liquid chromatography (HPLC). Several parameters on the recovery of the analyte were investigated. The experimental results showed that it was possible to obtain quantitative analysis when the solution pH was 6 using 200 mL of validation Solution containing 2 mu g of diazinon and 5 mL of acetonitrile as an eluent. Recovery of diazinon was 95.2 +/- 4.2% with a relative standard deviation for seven determinations of 4.9% under optimum conditions. The maximum preconcentration factor was 200 for diazinon when 1000 mL of sample solution volume was used. The linear range of calibration curve was 0.3 to 10,000 ng mL(-1) with a correlation coefficient of 0.997 and the detection limit (3S/N) was 0.06 ng mL(-1). The proposed method was successfully applied to the determination of diazinon in tap water with high precision and accuracy. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 29 条
[1]   Determination of diazinon, chlorpyrifos, and their metabolites in rat plasma and urine by high-performance liquid chromatography [J].
Abu-Qare, AW ;
Abou-Donia, MB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (05) :200-204
[2]   Monitoring of pesticide residues and their metabolites in surface and underground waters of Imathia (N. Greece) by means of solid-phase extraction disks and gas chromatography [J].
Albanis, TA ;
Hela, DG ;
Sakellarides, T ;
Konstantinou, IK .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :59-71
[3]   Trace determination of priority pesticides in water by means of high-speed on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry using turbulent-flow chromatography columns for enrichment and a short monolithic column for fast liquid chromatographic separation [J].
Asperger, A ;
Efer, J ;
Koal, T ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :109-119
[4]   Whole effluent toxicity of sewage treatment plants in the Hawkesbury-Nepean watershed, New South Wales, Australia, to Ceriodaphnia dubia and Selenastrum capricornutum [J].
Bailey, HC ;
Krassoi, R ;
Elphick, JR ;
Mulhall, AM ;
Hunt, P ;
Tedmanson, L ;
Lovell, A .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2000, 19 (01) :72-81
[5]  
Bailey HC, 2000, ENVIRON TOXICOL CHEM, V19, P82, DOI [10.1002/etc.5620190109, 10.1897/1551-5028(2000)019&lt
[6]  
0082:DACIUW&gt
[7]  
2.3.CO
[8]  
2]
[9]  
BJAMASON B, 1999, ANAL CHEM, V71, P2152
[10]   Determination of pesticide residues in coconut water by liquid-liquid extraction and gas chromatography with electron-capture plus thermionic specific detection and solid-phase extraction and high-performance liquid chromatography with ultraviolet detection [J].
Brito, NM ;
Navickiene, S ;
Polese, L ;
Jardim, EFG ;
Abakerli, RB ;
Ribeiro, ML .
JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) :201-209