Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI

被引:9
作者
Keilholz-George, SD
Knight-Scott, J
Berr, SS
机构
[1] Univ Virginia, Hlth Sci Ctr, Sch Engn, Engn Phys Program, Charlottesville, VA 22908 USA
[2] Univ Virginia, Hlth Sci Ctr, Dept Radiol, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22908 USA
关键词
arterial spin labeling; perfusion; imperfect slice profiles;
D O I
10.1002/mrm.1169
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Pulsed arterial spin labeling (ASL) techniques provide a noninvasive method of obtaining qualitative and quantitative perfusion images with MRI, ASL techniques employ inversion recovery and/or saturation recovery to induce perfusion weighting, and thus the performance of these techniques is dependent on the slice profiles of the inversion or saturation pulses. This article systematically examines through simulations the effects of slice profile imperfections on the perfusion signal for nine labeling schemes, including FAIR, FAIRER, and EST (UNFAIR), Each sequence is evaluated for quantitative accuracy, suppression of stationary signal, and magnitude of perfusion signal. Perfusion effects are modeled from a modified Bloch equation and experimentally determined slice profiles. The results show that FAIR, FAIRER, and EST have excellent tissue suppression. The magnitude of the perfusion signal is comparable for FAIR and FAIRER, with EST providing a slightly weaker signal. For quantitative measurements, all three methods underestimate the perfusion signal by more than 20%, Of the additional six ASL techniques examined, only one performed well in this model. This method, which combines inversion and saturation recovery, yields improved signal accuracy(< 15% difference from the theoretical value) and tissue suppression similar to that of FAIR and its variants, but has only half the signal. Magn Reson Med 46:141-148, 2001, (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 27 条
[1]  
Andersen IK, 2000, MAGN RESON IMAGING, V18, P565, DOI 10.1016/S0730-725X(00)00136-3
[2]  
Berr SS, 1999, JMRI-J MAGN RESON IM, V9, P146, DOI 10.1002/(SICI)1522-2586(199901)9:1<146::AID-JMRI19>3.0.CO
[3]  
2-C
[4]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[5]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[6]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[7]   Slice profile effects in adiabatic inversion: Application to multislice perfusion imaging [J].
Frank, LR ;
Wong, EC ;
Buxton, RB .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :558-564
[8]   Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR) [J].
Helpern, JA ;
Branch, CA ;
Yongbi, MN ;
Huang, NC .
MAGNETIC RESONANCE IMAGING, 1997, 15 (02) :135-139
[9]  
KARLSEN OT, 1996, P 4 ANN M ISMRM NEW
[10]   Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging [J].
Kim, SG ;
Tsekos, NV .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :425-435