Study of ionic-to-atomic line intensity ratios for two axial viewing-based inductively coupled plasma atomic emission spectrometers

被引:98
作者
Dennaud, J [1 ]
Howes, A [1 ]
Poussel, E [1 ]
Mermet, JM [1 ]
机构
[1] Univ Lyon 1, Analyt Sci Lab, F-69622 Villeurbanne, France
关键词
inductively coupled plasma; axial viewing; matrix effects; tonic-to-atomic line intensity ratio; buffer;
D O I
10.1016/S0584-8547(00)00299-8
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Using two axially-viewed inductively coupled plasma (ICP) systems that exhibited different behaviors to matrix effects, the sensitivity of the Mg II 280.270 nm/ Mg I 285.213 nm line intensity ratio to the ICP operating conditions and to matrix effects was compared to that observed for alternative ionic-to-atomic line intensity ratios such as the Cd II 226.502 nm/Cd I 228.802 nm, Cr II 267.716 nm/Cr I 357.868 nm, Ni II 231.604 nm/Ni I 232.138 nm, Pb II 220.353 nm/Pb I 217.000 nm, and Zn II 206.200 nm/Zn I 213.857 nm ratios. Both robust and non-robust conditions were used. Some lines behaved differently, in particular the Mg I and Cr I lines, not only as a function of the matrix, but also as a function of the TCP system. The Mg II/Mg I ratio was found to remain a good compromise to follow changes in plasma conditions. The use of several ionic-to-atomic line ratios confirmed that axial viewing leads to matrix effects that are particularly sensitive for atomic lines. The effects cannot be totally suppressed, even under robust conditions, and regardless of the ICP system. An alternative to minimize matrix effects was the use of a buffer such as Cs at 10 g l(-1). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:101 / 112
页数:12
相关论文
共 55 条
[1]  
Abdallah M.H., 1976, ANAL CHIM ACTA, V84, P329
[2]   SPECTROMETRIC STUDY ON RADIOFREQUENCY INDUCED PLASMA .1. ANALYTICAL PERFORMANCE [J].
ABDALLAH, MH ;
DIEMIASZONEK, R ;
JAROSZ, J ;
MERMET, JM ;
ROBIN, J ;
TRASSY, C .
ANALYTICA CHIMICA ACTA, 1976, 84 (02) :271-282
[3]   ELECTRONIC EXCITATION AND IONIZATION TEMPERATURE-MEASUREMENTS IN A HIGH-FREQUENCY INDUCTIVELY COUPLED ARGON PLASMA SOURCE AND THE INFLUENCE OF WATER-VAPOR ON PLASMA PARAMETERS [J].
ALDER, JF ;
BOMBELKA, RM ;
KIRKBRIGHT, GF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1980, 35 (04) :163-175
[4]  
[Anonymous], 1966, Theory of Spectrochemical Excitation
[5]   SOLID-STATE DETECTOR FOR ICP-OES [J].
BARNARD, TW ;
CROCKETT, MI ;
IVALDI, JC ;
LUNDBERG, PL ;
YATES, DA ;
LEVINE, PA ;
SAUER, DJ .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1231-1239
[6]   EFFECT OF SAMPLE AEROSOL TRANSPORT RATE ON INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION AND FLUORESCENCE [J].
BATES, LC ;
OLESIK, JW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (03) :239-247
[8]   EXPERIMENTAL-STUDY OF A 1-KW, 50-MHZ RF INDUCTIVELY COUPLED PLASMA WITH PNEUMATIC NEBULIZER, AND A DISCUSSION OF EXPERIMENTAL-EVIDENCE FOR A NONTHERMAL MECHANISM [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1977, 32 (9-10) :365-395
[10]   Comparison of axially and radially viewed inductively coupled plasmas for multi-element analysis: Effect of sodium and calcium [J].
Brenner, IB ;
Zander, A ;
Cole, M ;
Wiseman, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :897-906