Study of ionic-to-atomic line intensity ratios for two axial viewing-based inductively coupled plasma atomic emission spectrometers

被引:98
作者
Dennaud, J [1 ]
Howes, A [1 ]
Poussel, E [1 ]
Mermet, JM [1 ]
机构
[1] Univ Lyon 1, Analyt Sci Lab, F-69622 Villeurbanne, France
关键词
inductively coupled plasma; axial viewing; matrix effects; tonic-to-atomic line intensity ratio; buffer;
D O I
10.1016/S0584-8547(00)00299-8
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Using two axially-viewed inductively coupled plasma (ICP) systems that exhibited different behaviors to matrix effects, the sensitivity of the Mg II 280.270 nm/ Mg I 285.213 nm line intensity ratio to the ICP operating conditions and to matrix effects was compared to that observed for alternative ionic-to-atomic line intensity ratios such as the Cd II 226.502 nm/Cd I 228.802 nm, Cr II 267.716 nm/Cr I 357.868 nm, Ni II 231.604 nm/Ni I 232.138 nm, Pb II 220.353 nm/Pb I 217.000 nm, and Zn II 206.200 nm/Zn I 213.857 nm ratios. Both robust and non-robust conditions were used. Some lines behaved differently, in particular the Mg I and Cr I lines, not only as a function of the matrix, but also as a function of the TCP system. The Mg II/Mg I ratio was found to remain a good compromise to follow changes in plasma conditions. The use of several ionic-to-atomic line ratios confirmed that axial viewing leads to matrix effects that are particularly sensitive for atomic lines. The effects cannot be totally suppressed, even under robust conditions, and regardless of the ICP system. An alternative to minimize matrix effects was the use of a buffer such as Cs at 10 g l(-1). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:101 / 112
页数:12
相关论文
共 55 条
[21]   TOP-DOWN VERSUS SIDE-ON VIEWING OF THE INDUCTIVELY COUPLED PLASMA [J].
FAIRES, LM ;
BIENIEWSKI, TM ;
APEL, CT ;
NIEMCZYK, TM .
APPLIED SPECTROSCOPY, 1985, 39 (01) :5-9
[22]   INFLUENCE OF SOLUTION UPTAKE RATE ON SIGNALS AND INTERFERENCES IN INDUCTIVELY COUPLED PLASMA OPTICAL-EMISSION SPECTROMETRY [J].
FARINO, J ;
MILLER, JR ;
SMITH, DD ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1987, 59 (18) :2303-2309
[23]   INFLUENCE OF OPERATING-CONDITIONS ON THE EFFECTS OF ACIDS IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
FERNANDEZ, A ;
MURILLO, M ;
CARRION, N ;
MERMET, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :217-221
[24]   Multivariate investigation of matrix effects in inductively coupled plasma atomic emission spectrometry using pneumatic or ultrasonic nebulization [J].
Grotti, M ;
Magi, E ;
Frache, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (01) :89-95
[25]   Characterization of a 22 mm Torch for ICP-AES [J].
Horner, JA ;
Hieftje, GM .
APPLIED SPECTROSCOPY, 1999, 53 (06) :713-718
[26]   PERFORMANCE EVALUATION OF AN AXIALLY VIEWED HORIZONTAL INDUCTIVELY-COUPLED PLASMA FOR OPTICAL-EMISSION SPECTROMETRY [J].
IVALDI, JC ;
TYSON, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (10) :1207-1226
[27]   SPECTROMETRIC STUDY OF A 40-MHZ INDUCTIVELY COUPLED PLASMA .3. TEMPERATURES AND ELECTRON NUMBER DENSITY [J].
JAROSZ, J ;
MERMET, JM ;
ROBIN, JP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1978, 33 (3-4) :55-78
[28]   EXCITATION TEMPERATURES AND ELECTRON NUMBER DENSITIES EXPERIENCED BY ANALYTE SPECIES IN INDUCTIVELY COUPLED PLASMAS WITH AND WITHOUT PRESENCE OF AN EASILY IONIZED ELEMENT [J].
KALNICKY, DJ ;
FASSEL, VA ;
KNISELEY, RN .
APPLIED SPECTROSCOPY, 1977, 31 (02) :137-150
[29]   THE EFFECT OF ADDED HYDROGEN IN ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
MATOUSEK, JP ;
MERMET, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (6-7) :835-850
[30]   USE OF MAGNESIUM AS A TEST ELEMENT FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY DIAGNOSTICS [J].
MERMET, JM .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :85-94