Multivariate investigation of matrix effects in inductively coupled plasma atomic emission spectrometry using pneumatic or ultrasonic nebulization

被引:34
作者
Grotti, M [1 ]
Magi, E [1 ]
Frache, R [1 ]
机构
[1] Univ Genoa, Dipartimento Chim & Chim Ind, Sez Chim Analit & Ambientale, I-16146 Genoa, Italy
关键词
D O I
10.1039/a905416b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multivariate interference study was carried out using a low power inductively coupled plasma atomic emission spectrometer, after optimization of operating parameters in order to achieve both plasma robustness and maximum signal to background ratios. The method, based on the empirical modelling and experimental design concepts, provided a multivariate quantification of interferences caused by complex matrices containing Na, K, Ca, Al and Fe, at concentration levels ranging from 10 to 5000 mu g ml(-1), deducing the complex relationships between interfering effects and matrix composition. In order to test the plasma excitation conditions, the Mg II 280.270 nm to Mg I 285.213 nm line intensity ratio was measured for each combination of matrix elements. Both Meinhard and ultrasonic nebulization were considered for comparison.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 57 条
[1]   SPECTROMETRIC STUDY OF HIGH-FREQUENCY INDUCED PLASMA .2. DIFFERENT TYPES OF INTERFERENCES OBSERVED [J].
ABDALLAH, MH ;
MERMET, JM ;
TRASSY, C .
ANALYTICA CHIMICA ACTA, 1976, 87 (02) :329-339
[2]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[3]   THE VERTICAL SPATIAL CHARACTERISTICS OF ANALYTE EMISSION IN THE INDUCTIVELY COUPLED PLASMA [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :861-880
[4]   INTERFERENCE FROM EASILY IONIZABLE ELEMENT MATRICES IN INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY - A SPATIAL STUDY [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :881-900
[5]   STUDIES OF A RADIO-FREQUENCY INDUCTIVELY COUPLED ARGON PLASMA FOR OPTICAL EMISSION SPECTROMETRY .3. INTERFERENCE EFFECTS UNDER COMPROMISE CONDITIONS FOR SIMULTANEOUS MULTI-ELEMENT ANALYSIS [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1976, 31 (06) :355-375
[6]   System for automatic selection of operating conditions for inductively coupled plasma atomic emission spectroscopy [J].
Branagh, W ;
Whelan, C ;
Salin, ED .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1307-1315
[7]   Comparison of axially and radially viewed inductively coupled plasmas for multi-element analysis: Effect of sodium and calcium [J].
Brenner, IB ;
Zander, A ;
Cole, M ;
Wiseman, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :897-906
[8]   Ca and Na interference effects in an axially viewed ICP using low and high aerosol loadings [J].
Brenner, IB ;
Zischka, M ;
Maichin, B ;
Knapp, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) :1257-1264
[9]   Matrix effects in inductively coupled plasma atomic emission spectrometry using an ultrasonic nebulizer [J].
Budic, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :869-874
[10]   INFLUENCE OF THE SAMPLE INTRODUCTION SYSTEM ON ACID EFFECTS IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CARRE, M ;
LEBAS, K ;
MARICHY, M ;
MERMET, M ;
POUSSEL, E ;
MERMET, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :271-283