Multivariate investigation of matrix effects in inductively coupled plasma atomic emission spectrometry using pneumatic or ultrasonic nebulization

被引:34
作者
Grotti, M [1 ]
Magi, E [1 ]
Frache, R [1 ]
机构
[1] Univ Genoa, Dipartimento Chim & Chim Ind, Sez Chim Analit & Ambientale, I-16146 Genoa, Italy
关键词
D O I
10.1039/a905416b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multivariate interference study was carried out using a low power inductively coupled plasma atomic emission spectrometer, after optimization of operating parameters in order to achieve both plasma robustness and maximum signal to background ratios. The method, based on the empirical modelling and experimental design concepts, provided a multivariate quantification of interferences caused by complex matrices containing Na, K, Ca, Al and Fe, at concentration levels ranging from 10 to 5000 mu g ml(-1), deducing the complex relationships between interfering effects and matrix composition. In order to test the plasma excitation conditions, the Mg II 280.270 nm to Mg I 285.213 nm line intensity ratio was measured for each combination of matrix elements. Both Meinhard and ultrasonic nebulization were considered for comparison.
引用
收藏
页码:89 / 95
页数:7
相关论文
共 57 条
[41]   EASILY AND NONEASILY IONIZABLE ELEMENT MATRIX EFFECTS IN INDUCTIVELY COUPLED PLASMA OPTICAL SPECTROMETRY [J].
OLESIK, JW ;
WILLIAMSEN, EJ .
APPLIED SPECTROSCOPY, 1989, 43 (07) :1223-1232
[43]   SUPPRESSION OF ANALYTE SIGNAL BY VARIOUS CONCOMITANT SALTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
OLIVARES, JA ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1986, 58 (01) :20-25
[44]   THE ROLE OF ELECTRONS IN THE EMISSION ENHANCEMENT BY EASILY IONIZED ELEMENTS LOW IN THE INDUCTIVELY COUPLED PLASMA [J].
PRELL, LJ ;
MONNIG, C ;
HARRIS, RE ;
KOIRTYOHANN, SR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 (10-12) :1401-1410
[45]   A STEADY-STATE APPROACH TO EVALUATION OF PROPOSED EXCITATION MECHANISMS IN THE ANALYTICAL ICP [J].
RAYSON, GD ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (07) :683-697
[46]   INTERFERENCES IN A LOW-FLOW, LOW-POWER INDUCTIVELY COUPLED PLASMA [J].
REZAAIYAAN, R ;
OLESIK, JW ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1985, 40 :73-83
[47]   ANALYTICAL CHARACTERISTICS OF A LOW-FLOW, LOW-POWER INDUCTIVELY COUPLED PLASMA [J].
REZAAIYAAN, R ;
HIEFTJE, GM .
ANALYTICAL CHEMISTRY, 1985, 57 (02) :412-415
[48]   Influence of the operating conditions on the efficiency of internal standardization in inductively coupled plasma atomic emission spectrometry [J].
Romero, X ;
Poussel, E ;
Mermet, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (04) :487-493
[49]   The effect of sodium on analyte ionic line intensities in inductively coupled plasma atomic emission spectrometry: Influence of the operating conditions [J].
Romero, X ;
Poussel, E ;
Mermet, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (04) :495-502
[50]   SPATIAL PROFILES OF INTERELEMENT EFFECTS IN THE INDUCTIVELY COUPLED PLASMA [J].
RYBARCZYK, JP ;
JESTER, CP ;
YATES, DA ;
KOIRTYOHANN, SR .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2162-2170