Repeatability of monolithic HPLC columns while using a flow program

被引:14
作者
Kaminski, Lukas [1 ]
El Deeb, Sami [2 ]
Waetzig, Hermann [1 ]
机构
[1] Tech Univ Braunschweig, Inst Pharmaceut Chem, D-38106 Braunschweig, Germany
[2] Al Azhar Univ, Dept Pharmaceut Chem, Gaza, Israel
关键词
fast HPLC; flow programming; monolithic columns; repeatability;
D O I
10.1002/jssc.200700681
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
Fast HPLC methods are becoming more and more important. Using monolithic HPLC columns for fast separations, a flow program can be applied for further decrease in the total run time. An interesting issue was whether the flow program affects repeatability. The investigated method was a generic assay for the oral antidiabetic drugs glibenclamide and glimepiride in the presence of two of their degradation products. A flow program ranging from 5.0 to 9.9 mL/min had been set up to decrease the run time to approximately 1.7 min. Within-day RSD% (n = 40) for both retention times and peak areas were less than 1%. At flow rates higher than 7 mL/min, repeatability was impaired to some extent. It became mainly noticeable through the day-to-day precision (n = 60) which showed RSD% up to 2%. However, further investigations indicated that this was rather related to pump inefficiency at high flow rates than to the flow program as such. Presuming the use of appropriate equipment, qualified for high flow rates, the application of a flow program for shortening the run time is absolutely reasonable and does not affect repeatability.
引用
收藏
页码:1745 / 1749
页数:5
相关论文
共 7 条
[1]
The development and application of guidance on EQ of analytical instruments: High performance liquid chromatography [J].
Bedson, P ;
Rudd, D .
ACCREDITATION AND QUALITY ASSURANCE, 1999, 4 (1-2) :50-62
[2]
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[3]
*COUNC EUR, 1999, BRIT PHARM APP ID A1
[4]
A strategy to develop fast RP-HPLC methods using monolithic silica columns [J].
El Deeb, Sami ;
Preu, Lutz ;
Waetzig, Hermann .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (13) :1993-2001
[5]
Fast HPLC method for the determination of glimepiride, glibenclamide, and related substances using monolithic column and flow program [J].
El Deeb, Sami ;
Schepers, Udo ;
Waetzig, Hermann .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (11) :1571-1577
[6]
Wide concentration range investigation of recovery, precision and error structure in liquid chromatography [J].
Schepers, U ;
Ermer, J ;
Preu, L ;
Wätzig, H .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (01) :111-118
[7]
Fast separations on monolithic silica columns: method transfer, robustness and column ageing for some case studies [J].
van Nederkassel, AM ;
Aerts, A ;
Dierick, A ;
Massart, DL ;
Vander Heyden, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (02) :233-249