Midterm results of stent-craft repair for thoracic aortic aneurysms: Computed tomographic evaluation

被引:15
作者
Yamazaki, I [1 ]
Imoto, K [1 ]
Suzuki, S [1 ]
Ichikawa, Y [1 ]
Karube, N [1 ]
Manabe, T [1 ]
Noishiki, Y [1 ]
Kondo, J [1 ]
Takanashi, Y [1 ]
机构
[1] Yokohama City Univ, Sch Med, Dept Surg 1, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
关键词
stent graft; thoracic aortic aneurysm; endoleak; ulcerlike projection; midterm results of endovascular surgery; computed tomography; thrombus organization;
D O I
10.1046/j.1525-1594.2001.025003223.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Midterm observation of endovascular surgery using a fabric-covered stent graft for thoracic aortic aneurysms is discussed with postoperative follow-up findings based on regularly performed thoracic computed tomography (CT). From 1996 to 1999, 20 patients with thoracic aortic aneurysm underwent stent-graft placement in our hospital. One year follow-up CT results after placement were obtained for 17 patients. The CT scans found that there were both thrombosis and size reduction of aneurysm in 8 patients (46%), thrombosis without size reduction in 2 (13%), a new ulcerlike projection (ULP) in 3 (19%), persistent minor endoleakage in 2 (13%), a new endoleak in 1 (6%), and a recurrent endoleak from intercostal arteries in 1 (6%). The new ULP formation seemed to be a peculiar problem stemming from an intimal injury caused by edges of the stent. Therefore, we recently adopted a new spiral stent instead of the previous stent to avoid the injury. The new endoleak suggested that aneurysmal thrombosis without size reduction could cause the aneurysm to develop recurrent endoleaks. From these findings, we concluded that midterm observation of stent-graft repair for thoracic aortic aneurysms did not give satisfactory results. In order to improve the results of endovascular surgery using stent-grafts, we need to develop safer stent grafts with a reliable design to prevent endoleaks and to avoid intimal injury of the aorta. We also hope to develop effective technologies that can accelerate organization of thrombus in the aortic aneurysm after stent-graft placement.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 8 条
[1]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[2]  
Dorros G, 1996, J ENDOVASC SURG, V3, P270, DOI 10.1583/1074-6218(1996)003<0270:AITCAE>2.0.CO
[3]  
2
[4]  
MATSUMOTO A, 1999, STENTGRAFT
[5]   Thoracic aortic aneurysm repair with an endovascular stent graft: The "first generation" [J].
Mitchell, RS ;
Miller, DC ;
Dake, MD ;
Semba, CP ;
Moore, KA ;
Sakai, T .
ANNALS OF THORACIC SURGERY, 1999, 67 (06) :1971-1974
[6]   Descending thoracic aortic aneurysm: Thoracic CT findings after endovascular stent-graft placement [J].
Sakai, T ;
Dake, MD ;
Semba, CP ;
Yamada, T ;
Arakawa, A ;
Kee, ST ;
Hayashi, N ;
Razavi, MK ;
Sze, DY .
RADIOLOGY, 1999, 212 (01) :169-174
[7]  
Semba C P, 1997, Vasc Med, V2, P98
[8]   Stent-graft treatment of type B aortic dissection involving the right aortic arch - Case report [J].
Yamazaki, I ;
Imoto, K ;
Ichikawa, Y ;
Kondo, J ;
Takanashi, Y .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (09) :727-728