Transthoracic monitoring of the impedance of the right lung in patients with cardiogenic pulmonary edema

被引:21
作者
Charach, G [1 ]
Rabinovich, P [1 ]
Grosskopf, I [1 ]
Weintraub, M [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Dept Internal Med c, Tel Aviv Sourasky Med Ctr, IL-69978 Tel Aviv, Israel
关键词
impedance monitor; internal thoracic impedance; monitoring of pulmonary edema;
D O I
10.1097/00003246-200106000-00008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the suitability of the new electrical impedance monitor RS-205 for monitoring of cardiogenic pulmonary edema (CPE). Design: Prospective, controlled study. Setting: A department of internal medicine in a 1,200-bed university-affiliated, teaching hospital. Patients: Sixty patients, aged 52-80 yrs, 30 without CPE (controls) and 30 with or at high risk for CPE. Interventions: Internal thoracic impedance (ITI) was monitored by the RS-205. The RS-205 is approximately three times more sensitive than the Kubicek monitor, and it eliminates the effect of the drift of skin-to-electrode impedance. This is achieved by eliminating skin electrode impedance by a special algorithm, thus allowing measurement of ITI rather than total transthoracic impedance. Measuring ITI, the main component of which is lung impedance, is a noninvasive and safe method. CPE was diagnosed in accordance with well-accepted clinical and roentgenological criteria. Measurements and Main Results: The controls' initial ITI was 68.3 +/- 12.38 ohms. During 6 hrs of monitoring, the ITI attained a minimum average value of -1.3 +/- 2.08% and a maximum average value of 4.6 +/- 3.56% relative to baseline. In all patients entering CPE, ITI decreased by 14.4 +/- 5.42% on the average (p < .001) 1 hr before the appearance of clinical symptoms. In patients with evolving CPE, ITI decreased significantly compared with controls (22.25 +/- 9.82%, p < .001). In patients at the peak of pulmonary edema, ITI was 2.1 times lower than in the control group (33.1 +/- 10.90 ohms, p < .001). In the last hour before the resolution of CPE, ITI increased in all patients by 17.7 +/- 19.74% compared with the peak of disease (p < .05). After the resolution of pulmonary edema, ITI increased in all patients by 44.14 +/- 26.90% compared with the peak of disease (p < .001). Importantly, the trend in ITI in all patients changed in accordance with the dynamics of CPE. A mixed general linear model shows that ITI values correlated well with the degree of crepitation, a direct characteristics of CPE. Conclusions: The RS-205 is suitable for monitoring patients at high risk of CPE development. It enables detection of CPE and the monitoring of patients at all stages of CPE.
引用
收藏
页码:1137 / 1144
页数:8
相关论文
共 28 条
[1]  
Anderson FA, 1980, ENCY MED DEVICES INS, V3, P1632
[2]  
[Anonymous], 1980, PRACTICAL NONPARAMET
[3]   COMPARISON OF DOUBLE INDICATOR THERMODILUTION MEASUREMENTS OF EXTRA-VASCULAR LUNG WATER (EVLW) WITH RADIOGRAPHIC ESTIMATION OF LUNG WATER IN TRAUMA PATIENTS [J].
BAUDENDISTEL, L ;
SHIELDS, JB ;
KAMINSKI, DL .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1982, 22 (12) :983-988
[4]  
BERL R, 1971, ARCH SURG-CHICAGO, V102, P61
[5]  
BRAUNWALD E, 1997, HEART DIS, V1, P171
[6]   DETECTION OF CHANGES IN INTRATHORACIC FLUID IN MAN USING ELECTRICAL-IMPEDANCE TOMOGRAPHY [J].
CAMPBELL, JH ;
HARRIS, ND ;
ZHANG, F ;
MORICE, AH ;
BROWN, BH .
CLINICAL SCIENCE, 1994, 87 (01) :97-101
[7]   PARAMETERS OF TRANSTHORACIC ELECTRICAL CONDUCTION [J].
COOLEY, WL .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1970, 170 (02) :702-&
[8]  
CROPPER MA, 1994, CLIN CHEST MED, V15, P501
[9]   EVALUATION OF TRANS-THORACIC ELECTRICAL-IMPEDANCE IN THE DIAGNOSIS OF PULMONARY-EDEMA [J].
FEIN, A ;
GROSSMAN, RF ;
JONES, JG ;
GOODMAN, PC ;
MURRAY, JF .
CIRCULATION, 1979, 60 (05) :1156-1160
[10]   THE EFFICIENCY OF SOME NONPARAMETRIC COMPETITORS OF THE T-TEST [J].
HODGES, JL ;
LEHMANN, EL .
ANNALS OF MATHEMATICAL STATISTICS, 1956, 27 (02) :324-335