Direct Voltammetric Detection of DNA and pH Sensing on Epitaxial Graphene: An Insight into the Role of Oxygenated Defects

被引:204
作者
Lim, Cheng Xiang [1 ]
Hoh, Hui Ying [1 ]
Ang, Priscilla Kailian [1 ]
Loh, Kian Ping [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
关键词
URIC-ACID; ELECTROCHEMICAL PERFORMANCE; CARBON ELECTRODES; ASCORBIC-ACID; DOPAMINE; DIAMOND; FILM; PLATFORM;
D O I
10.1021/ac101519v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we carried out detailed electrochemical studies of epitaxial graphene (EG) using inner-sphere and outer-sphere redox mediators. The EG sample was anodized systematically to investigate the effect of edge plane defects on the heterogeneous charge transfer kinetics and capacitive noise. We found that anodized EG, consisting of oxygen-related defects, is a superior biosensing platform for the detection of nucleic acids, uric acids (UA), dopamine (DA), and ascorbic acids (AA). Mixtures of nucleic acids (A, T, C, G) or biomolecules (AA, UA, DA) can be resolved as individual peaks using differential pulse voltammetry. In fact, an anodized EG voltammetric sensor can realize the simultaneous detection of all four DNA bases in double stranded DNA (dsDNA) without a prehydrolysis step, and it can also differentiate single stranded DNA from dsDNA. Our results show that graphene with high edge plane defects, as opposed to pristine graphene, is the choice platform in high resolution electrochemical sensing.
引用
收藏
页码:7387 / 7393
页数:7
相关论文
共 35 条
  • [21] Electrochemical analysis of nucleic acids at boron-doped diamond electrodes
    Prado, C
    Flechsig, GU
    Gründler, P
    Foord, JS
    Marken, F
    Compton, RG
    [J]. ANALYST, 2002, 127 (03) : 329 - 332
  • [22] The role of oxygen functionalities and edge plane sites on screen-printed carbon electrodes for simultaneous determination of dopamine, uric acid and ascorbic acid
    Prasad, K. Sudhakara
    Muthuraman, Govindan
    Zen, Jyh-Myng
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (04) : 559 - 563
  • [23] Band-edge movements of semiconducting diamond in aqueous electrolyte induced by anodic surface treatment
    Rao, TN
    Tryk, DA
    Hashimoto, K
    Fujishima, A
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (02) : 680 - 684
  • [24] QUANTITATIVE RELATIONSHIP BETWEEN ELECTRON-TRANSFER RATE AND SURFACE MICROSTRUCTURE OF LASER-MODIFIED GRAPHITE-ELECTRODES
    RICE, RJ
    MCCREERY, RL
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (15) : 1637 - 1641
  • [25] Richards J, 1996, J NEPHROL, V9, P160
  • [26] Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode
    Safavi, Afsaneh
    Maleki, Norouz
    Moradlou, Omran
    Tajabadi, Fariba
    [J]. ANALYTICAL BIOCHEMISTRY, 2006, 359 (02) : 224 - 229
  • [27] Catalyst-Free Efficient Growth, Orientation and Biosensing Properties of Multilayer Graphene Nanoflake Films with Sharp Edge Planes
    Shang, Nai Gui
    Papakonstantinou, Pagona
    McMullan, Martin
    Chu, Ming
    Stamboulis, Artemis
    Potenza, Alessandro
    Dhesi, Sarnjeet S.
    Marchetto, Helder
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2008, 18 (21) : 3506 - 3514
  • [28] Electrical properties of diamond surfaces
    Shirafuji, J
    Sugino, T
    [J]. DIAMOND AND RELATED MATERIALS, 1996, 5 (6-8) : 706 - 713
  • [29] Tang L., 2009, ADV FUNCT MATER, V19, P1
  • [30] Electronic structure of epitaxial graphene layers on SiC: Effect of the substrate
    Varchon, F.
    Feng, R.
    Hass, J.
    Li, X.
    Nguyen, B. Ngoc
    Naud, C.
    Mallet, P.
    Veuillen, J.-Y.
    Berger, C.
    Conrad, E. H.
    Magaud, L.
    [J]. PHYSICAL REVIEW LETTERS, 2007, 99 (12)