Effective sensitivity in 3D PET: The impact of detector dead time on 3D system performance

被引:7
作者
Bailey, DL
Meikle, SR
Jones, T
机构
[1] MRC Cyclotron Unit, Hammersmith Hospital
关键词
D O I
10.1109/23.596984
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
3D PET has higher sensitivity than 2D PET. Sensitivity is dependant on detector properties such as density, stopping power, photofraction, etc, but for a given detcetor material the sensitivity of a tomograph is primarily determined by two components: the geometric solid angle for detection, and the fractional dead time, i.e., the time for which the detector is unavailable for accepting events. The loss in overall sensitivity as a function of radioactivity concentration due to these factors for 3D PET has been characterised by a parameter, the effective sensitivity, which combines absolute sensitivity and noise equivalent count rates. This parameter includes scatter, system sensitivity, dead time, and random coincidence rates, and permits comparisons between different tomographs as well as the same tomograph under different conditions. Effective sensitivity decreases most rapidly for larger, open 3D tomographs. The loss in effective sensitivity with increasing count rate suggests that new faster scintillation detectors will be needed to realize the sensitivity gain of 3D PET over a wide dynamic range of radioactivity concentrations.
引用
收藏
页码:1180 / 1185
页数:6
相关论文
共 11 条
[1]   A METHOD FOR MEASURING THE ABSOLUTE SENSITIVITY OF POSITRON EMISSION TOMOGRAPHIC SCANNERS [J].
BAILEY, DL ;
JONES, T ;
SPINKS, TJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (06) :374-379
[2]   NOISE EQUIVALENT COUNT MEASUREMENTS IN A NEURO-PET SCANNER WITH RETRACTABLE SEPTA [J].
BAILEY, DL ;
JONES, T ;
SPINKS, TJ ;
GILARDI, MC ;
TOWNSEND, DW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :256-260
[3]   ECAT ART - A continuously rotating PET camera: Performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department [J].
Bailey, DL ;
Young, H ;
Bloomfield, PM ;
Meikle, SR ;
Glass, D ;
Myers, MJ ;
Spinks, TJ ;
Watson, CC ;
Luk, P ;
Peters, AM ;
Jones, T .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (01) :6-15
[4]  
BAILEY DL, 1993, INT CONGR SER, V1030, P341
[5]  
Diffrient Niels, 1974, HUMAN SCALE 1 2 3
[6]  
Jones T, 1996, J NUCL MED, V37, P331
[7]  
KARP JS, 1991, J NUCL MED, V32, P2342
[8]   CERIUM-DOPED LUTETIUM OXYORTHOSILICATE - A FAST, EFFICIENT NEW SCINTILLATOR [J].
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :502-505
[9]  
RAKSHI J, 1996, QUANTIFICATION BRAIN, P82
[10]   MEASURING PET SCANNER SENSITIVITY - RELATING COUNTRATES TO IMAGE SIGNAL-TO-NOISE RATIOS USING NOISE EQUIVALENT COUNTS [J].
STROTHER, SC ;
CASEY, ME ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :783-788