Clinical efficacy of a wearable defibrillator in acutely terminating episodes of ventricular fibrillation using biphasic shocks

被引:51
作者
Reek, S
Geller, JC
Meltendorf, U
Wollbrueck, A
Szymkiewicz, SJ
Klein, HU
机构
[1] Univ Hosp Magdeburg, Div Cardiol, D-39120 Magdeburg, Germany
[2] LIFECOR Inc, Pittsburgh, PA USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 10期
关键词
defibrillation; sudden cardiac death; ventricular fibrillation; resuscitation;
D O I
10.1046/j.1460-9592.2003.00311.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The Wearable Cardioverter Defibrillator (WCD) automatically detects and treats ventricular tachyarrhythmias without the need for assistance from a bystander, while at the same time allowing,the patient to ambulate freely. It represents an alternative to emergency medical services for outpatient populations with a temporary risk of sudden cardiac death. While the original devices used a monophasic truncated exponential waveform for cardioversion/defibrillation shocks, a new, biphasic shock was developed for the next device generation. In 12 patients undergoing electrophysiological testing for ventricular tachyarrhythmias, termination of electrically induced ventricular fibrillation (VF) was attempted via the WCD. In 22 episodes, induced VF was promptly terminated by the first 70 J (n = 12) or 100 J (n = 10) biphasic shocks. Time between arrhythmia initiation and shock delivery was 22 +/- 6 seconds (70 J) and 21 +/- 6 seconds (100 J) (P = NS). The measured transthoracic impedance was 71 +/- 5 Ohm (64-79 Ohm) for the 70 J shock and 64 +/- 8 Ohm (47-72 Ohm) for the 100 J shock. The present study demonstrates that a single low energy biphasic shock delivered by the WCD, reliably terminates electrically induced VF (100% of episodes). The results of this study suggest that there is an acceptable safety margin to the maximum output of the device (150 J). Despite our promising data, we recommend that programming all shocks for maximum energy output should be done when using the WCD in ambulatory patients.
引用
收藏
页码:2016 / 2022
页数:7
相关论文
共 37 条
[1]
Clinical efficacy of the wearable cardioverter-defibrillator in acutely terminating episodes of ventricular fibrillation [J].
Auricchio, A ;
Klein, H ;
Geller, CJ ;
Reek, S ;
Heilamn, MS ;
Szymkiewicz, SJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (10) :1253-+
[2]
TRUNCATED BIPHASIC PULSES FOR TRANSTHORACIC DEFIBRILLATION [J].
BARDY, GH ;
GLINER, BE ;
KUDENCHUK, PJ ;
POOLE, JE ;
DOLACK, GL ;
JONES, GK ;
ANDERSON, J ;
TROUTMAN, C ;
JOHNSON, G .
CIRCULATION, 1995, 91 (06) :1768-1774
[3]
Multicenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic ventricular defibrillation [J].
Bardy, GH ;
Marchlinski, FE ;
Sharma, AD ;
Worley, SJ ;
Luceri, RM ;
Yee, R ;
Halperin, BD ;
Fellows, CL ;
Ahern, TS ;
Chilson, DA ;
Packer, DL ;
Wilber, DJ ;
Mattioni, TA ;
Reddy, R ;
Kronmal, RA ;
Lazzara, R .
CIRCULATION, 1996, 94 (10) :2507-2514
[4]
A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
MEHRA, R ;
GREENE, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :728-733
[5]
A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[6]
COMPARISON OF MONOPHASIC WITH SINGLE AND DUAL CAPACITOR BIPHASIC WAVEFORMS FOR NONTHORACOTOMY CANINE INTERNAL DEFIBRILLATION [J].
CHAPMAN, PD ;
VETTER, JW ;
SOUZA, JJ ;
WETHERBEE, JN ;
TROUP, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (01) :242-245
[7]
IMPROVED INTERNAL DEFIBRILLATION EFFICACY WITH A BIPHASIC WAVEFORM [J].
FAIN, ES ;
SWEENEY, MB ;
FRANZ, MR .
AMERICAN HEART JOURNAL, 1989, 117 (02) :358-364
[8]
Feldman AM, 2002, J AM COLL CARDIOL, V39, p101A
[9]
TRANSTHORACIC DEFIBRILLATION OF SWINE WITH MONOPHASIC AND BIPHASIC WAVE-FORMS [J].
GLINER, BE ;
LYSTER, TE ;
DILLION, SM ;
BARDY, GH .
CIRCULATION, 1995, 92 (06) :1634-1643
[10]
Gliner Bradford E., 1998, Biomedical Instrumentation and Technology, V32, P631