The use of gold bands for flow immunoelectrochemical devices

被引:5
作者
Abad-Villar, EM [1 ]
Fernández-Abedul, MT [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Asturias, Spain
关键词
gold bands (films); enzyme immunoassays; electrochemical immunoassays; flow systems;
D O I
10.1007/s00216-003-2122-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gold bands sputtered over a polymeric material, Kapton, have been employed not only for electrochemical detection but also for the development of enzyme immunoassays in a flow system. The immunological interactions on bands acting as reactors are considered for a model analyte, IgM. Different formats of flow immunoassays, competitive and non-competitive, have been checked. Compared with previous results, automation gives rise to in a reduction in analysis time and in reagent consumption. Lower limits of detection are also obtained. Detection, which is also carried out in the flow system, is based on the oxidation of naphthol, the product of the enzymatic hydrolysis of naphthyl-phosphate.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 19 条
  • [1] Simultaneous and sequential enzyme immunoassays on gold bands with flow electrochemical detection
    Abad-Villar, EM
    Fernández-Abedul, MT
    Costa-García, A
    [J]. ANALYTICA CHIMICA ACTA, 2002, 453 (01) : 63 - 69
  • [2] Gold bands as a suitable surface for enzyme immunoassays
    Abad-Villar, EM
    Fernández-Abedul, MT
    Costa-García, A
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) : 797 - 802
  • [3] Flow injection electrochemical enzyme immunoassay based on the use of gold bands
    Abad-Villar, EM
    Fernández-Abedul, MT
    Costa-García, A
    [J]. ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) : 149 - 158
  • [4] Thin-film gold electrodes produced by magnetron sputtering. Voltammetric characteristics and application in batch injection analysis with amperometric detection
    Brett, AMO
    Matysik, FM
    Vieira, MT
    [J]. ELECTROANALYSIS, 1997, 9 (03) : 209 - 212
  • [5] Burtis C.A., 1994, Tietz Textbook of Clinical Chemistry
  • [6] Concheso-Suarez RI, 1998, QUIM ANAL, V17, P35
  • [7] Development and characterization of an ELISA assay in PDMS microfluidic channels
    Eteshola, E
    Leckband, D
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (02) : 129 - 133
  • [8] Fernández-Abedul MT, 2002, C T COL I S, V3, P55
  • [9] Antibodies for immunosensors - A review
    Hock, B
    [J]. ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 177 - 186
  • [10] Kissinger PT., 1996, LAB TECHNIQUES ELECT, Vsecond, DOI DOI 10.1016/S0165-9936(96)80740-0