Simultaneous and sequential enzyme immunoassays on gold bands with flow electrochemical detection

被引:7
作者
Abad-Villar, EM [1 ]
Fernández-Abedul, MT [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Asturias, Spain
关键词
gold bands (films); enzyme immunoassays; electrochemical immunoassay; simultaneous immunoassay; sequential immunoassay; FIA;
D O I
10.1016/S0003-2670(01)01492-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of carrying out enzyme (AP) immumoassays on thin gold bands is demonstrated here for the determination of an analyte (IgG) model, following two different formats: simultaneous and sequential. The detection, that also employs a gold band as the working electrode of the potentionstatic system, is amperometrically performed in a flow system. After the reaction between IgG and IgG-AP for binding anti-IgG places, the enzymatic hydrolysis of naphthylphosphate occurs. The naphtol generated in the immunoreactor is conducted to the detector where it is oxidised to naphtoquinone providing highly reproducible analytical signals. Comparison of both formats of immunoassays was made in terms of analysis time and sensitivity. Since the gold bands where the immunoreactions took place have to be inserted in the,flow system for the detection, a novel single flow cell that enabled their rapid insertion was specially designed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 41 条
  • [1] Flow injection electrochemical enzyme immunoassay based on the use of gold bands
    Abad-Villar, EM
    Fernández-Abedul, MT
    Costa-García, A
    [J]. ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) : 149 - 158
  • [2] ABADVILLAR EM, 2001, BIOSENS BIOELECTRON
  • [3] Highly sensitive flow-injection immunoassay system for rapid detection of bacteria
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) : 99 - 108
  • [4] AVIDIN-BIOTIN BASED ELECTROCHEMICAL IMMUNOASSAY FOR THYROTROPIN
    ATHEY, D
    BALL, M
    MCNEIL, CJ
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 : 570 - 577
  • [5] FORMATION OF MONOLAYER FILMS BY THE SPONTANEOUS ASSEMBLY OF ORGANIC THIOLS FROM SOLUTION ONTO GOLD
    BAIN, CD
    TROUGHTON, EB
    TAO, YT
    EVALL, J
    WHITESIDES, GM
    NUZZO, RG
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (01) : 321 - 335
  • [6] Automated amplified flow immunoassay for cocaine
    Bauer, CG
    Eremenko, AV
    Kühn, A
    Kürzinger, K
    Makower, A
    Scheller, FW
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (21) : 4624 - 4630
  • [7] Bengoechea Alvarez M. Jose, 2001, Analytica Chimica Acta, V442, P55
  • [8] Thin-film gold electrodes produced by magnetron sputtering. Voltammetric characteristics and application in batch injection analysis with amperometric detection
    Brett, AMO
    Matysik, FM
    Vieira, MT
    [J]. ELECTROANALYSIS, 1997, 9 (03) : 209 - 212
  • [9] CIANA LD, 1995, J ELECTROANAL CHEM, V382, P129
  • [10] Concheso-Suarez RI, 1998, QUIM ANAL, V17, P35