Highly sensitive flow-injection immunoassay system for rapid detection of bacteria

被引:66
作者
Abdel-Hamid, I [1 ]
Ivnitski, D [1 ]
Atanasov, P [1 ]
Wilkins, E [1 ]
机构
[1] Univ New Mexico, Dept Chem & Nucl Engn, Albuquerque, NM 87131 USA
关键词
amperometric biosensor; immunofiltration flow-injection assay; Salmonella; E-coli;
D O I
10.1016/S0003-2670(99)00580-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection amperometric immunofiltration assay system for the rapid detection of total Escherichia coli and Salmonella was developed. The system is based on the use of disposable porous nylon membranes which act as a support for the immobilization of anti-E. coli or anti-Salmonella antibodies. The assay system consists of a flow-injection system, a disposable filter-membrane and an amperometric sensor. Parameters affecting the performance of the immunofiltration assay system such as membrane pore size, non-specific binding, conjugate concentration and sample volume were studied and optimized. A sandwich scheme of immunoassay was employed and the immunofiltration system was able to specifically and directly detect 50 cells/ml of total E. coli or 50 cells/ml of Salmonella with an overall analysis time of 35 min. This immunosensor can be easily adapted for the assay of other microorganisms and may be a basis for a new class of highly sensitive and automated bioanalytical devices for the rapid quantitative detection of bacteria. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 36 条
  • [1] Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) : 309 - 316
  • [2] Development of a flow-through immunoassay system
    Abdel-Hamid, I
    Atanasov, P
    Ghindilis, AL
    Wilkins, E
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 49 (03) : 202 - 210
  • [3] Abdel-Hamid I, 1998, ELECTROANAL, V10, P758, DOI 10.1002/(SICI)1521-4109(199809)10:11<758::AID-ELAN758>3.0.CO
  • [4] 2-5
  • [5] Accelerated detection of DNA on membranes by automated enzyme-linked immunofiltration assay
    Aubert, D
    Toubas, D
    Foudrinier, F
    Villena, I
    Gomez, JE
    Marx, C
    Lepan, H
    Lemaire, P
    Jacquier, P
    Bonhomme, A
    Pinon, JM
    [J]. ANALYTICAL BIOCHEMISTRY, 1997, 247 (01) : 25 - 29
  • [6] Beran G. W., 1991, Dairy, Food and Environmental Sanitation, V11, P189
  • [7] DEVELOPMENT OF A FLOW-INJECTION ANALYSIS (FIA) IMMUNOSENSOR FOR THE DETECTION OF ESCHERICHIA-COLI
    BOUVRETTE, P
    LUONG, JHT
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1995, 27 (2-3) : 129 - 137
  • [8] DETECTION OF STAPHYLOCOCCUS-AUREUS WITH BIOTINYLATED MONOCLONAL-ANTIBODIES DIRECTED AGAINST STAPHYLOCOCCAL TNASE COMPLEXED TO AVIDIN-PEROXIDASE IN A RAPID SANDWICH ENZYME-LINKED IMMUNOFILTRATION ASSAY (SELIFA)
    BRAKSTAD, OG
    MAELAND, JA
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1993, 39 (02) : 128 - 134
  • [9] Buchanan RL, 1997, FOOD TECHNOL-CHICAGO, V51, P69
  • [10] DESHPANDE SS, 1994, FOOD TECHNOL-CHICAGO, V48, P146