MRI detection of weak magnetic fields due to an extended current dipole in a conducting sphere: A model for direct detection of neuronal currents in the brain

被引:74
作者
Konn, D [1 ]
Gowland, P [1 ]
Bowtell, R [1 ]
机构
[1] Univ Nottingham, Sch Phys & Astron, Magnet Resonance Ctr, Nottingham NG7 2RD, England
关键词
current dipole; neuronal current; MR phase; direct neuronal detection; spherical conductor;
D O I
10.1002/mrm.10494
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate the feasibility of direct MR detection of neuronal activity in the brain, neuronal current flow was modeled as an extended current dipole located in a conducting sphere. The spatially varying magnetic field induced within the sphere by such a dipole was calculated, including its form close to and within the current source. The predicted field variation was experimentally verified by measurements of the variation in phase of the MR signal in a sphere containing a model dipole. The effects of the calculated magnetic field distributions on the phase and magnitude of the signal in MR images were explored. The minimum detectable dipole strength under normal experimental conditions was calculated to be about 4.5 nAm, which is similar in magnitude to dipole strengths from evoked neuronal activity, and is an order of magnitude smaller than dipole strengths expected from spontaneous activity. This minimum detectable dipole strength increases with increasing spatial extent of the primary current distribution. In the experimental work, the effects of a field of [1.1 +/- 0.5] x 10(-10) T strength were detected, corresponding to the maximum net field caused by a dipole of 6.3 nAm strength with a spatial extent of 3 x 3 x 2 mm(3). Magn Reson Mad 50:40-49, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:40 / 49
页数:10
相关论文
共 25 条
[1]   Spatiotemporal activity of a cortical network for processing visual motion revealed by MEG and fMRI [J].
Ahlfors, SP ;
Simpson, GV ;
Dale, AM ;
Belliveau, JW ;
Liu, AK ;
Korvenoja, A ;
Virtanen, J ;
Huotilainen, M ;
Tootell, RBH ;
Aronen, HJ ;
Ilmoniemi, RJ .
JOURNAL OF NEUROPHYSIOLOGY, 1999, 82 (05) :2545-2555
[2]   Spatial heterogeneity of the nonlinear dynamics in the FMRI BOLD response [J].
Birn, RM ;
Saad, ZS ;
Bandettini, PA .
NEUROIMAGE, 2001, 14 (04) :817-826
[3]   Current-induced magnetic resonance phase imaging [J].
Bodurka, J ;
Jesmanowicz, A ;
Hyde, JS ;
Xu, H ;
Estkowski, L ;
Li, SJ .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :265-271
[4]   Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic fields changes [J].
Bodurka, J ;
Bandettini, PA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1052-1058
[5]   Linear systems analysis of functional magnetic resonance imaging in human V1 [J].
Boynton, GM ;
Engel, SA ;
Glover, GH ;
Heeger, DJ .
JOURNAL OF NEUROSCIENCE, 1996, 16 (13) :4207-4221
[6]   ECCENTRIC DIPOLE IN A SPHERICAL MEDIUM - GENERALIZED EXPRESSION FOR SURFACE POTENTIALS [J].
BRODY, DA ;
TERRY, FH ;
IDEKER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (02) :141-143
[7]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[8]   INFLOW VERSUS DEOXYHEMOGLOBIN EFFECTS IN BOLD FUNCTIONAL MRI USING GRADIENT ECHOES AT 1.5 T [J].
DUYN, JH ;
MOONEN, CTW ;
VANYPEREN, GH ;
DEBOER, RW ;
LUYTEN, PR .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :83-88
[9]   BRAIN OR VEIN-OXYGENATION OR FLOW - ON SIGNAL PHYSIOLOGY IN FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W ;
KLEINSCHMIDT, A ;
BOECKER, H .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :45-53
[10]   Nonlinear event-related responses in fMRI [J].
Friston, KJ ;
Josephs, O ;
Rees, G ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) :41-52