Flow injection analysis of sulfite ion with a potentiometric titanium phosphate-epoxy based membrane sensor

被引:28
作者
Hassan, SSM [1 ]
Marei, SA
Badr, IH
Arida, HA
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
[2] Atom Energy Author, Hot Lab Ctr, Inshas, Egypt
关键词
inorganic ion exchangers; sulfite sensor; potentiometry; flow injection analysis; gas dialyzer; titanium phosphate ion exchanger; epoxy membrane;
D O I
10.1016/S0039-9140(01)00330-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric sensor based on the use of titanium phosphate (TP) in epoxy matrix membrane is prepared and characterized. The sensor exhibits near-Nernstian response for many anionic species over the concentration range 10 (-1)-10 (- 5) mol l(-1). The origin of response is explained on the basis of the conversion of titanium phosphate cation exchanger into hydrated titanium oxide anion exchanger by the effect of the high pH of the epoxy matrix. The sensitivity and selectivity of the sensor for sulfite ions are optimized by conversion of sulfite into gaseous SO, by acidification, and diffusion of the gas through a membrane-based gas dialyzer followed by potentiometric detection of sulfite ions formed within a flowing recipient stream. No interferences are caused by many common anions and acidic gas releasing species except sulfide and nitrite ions. Determination of sulfite ion at levels as low as 10(-4) mol l(-1) or less in the presence of nitrite and sulfide ions is performed by using a modified carrier buffer stream (10 (-2) mol l(-1) MES, pH 5.0 containing sulfamic acid) and pretreatment with Pb2+. Advantages offered by the proposed gas dialyzer/flow injection system with TP-epoxy membrane based sensor over traditional ion exchange based sensors includes long life time ( > 8 months), excellent stability and reproducibility ( similar to 1 mV), fast response time ( < 30 s), wide pH working range (pH 5-9). high sample throughput ( similar to 60 samples h(-1)). low detection limit (8 x 10(-6) mol l(-1))and high thermal stability (up to 80 degreesC). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:773 / 782
页数:10
相关论文
共 40 条
[1]   NEW SPECTROPHOTOMETRIC METHOD FOR SULFITE DETERMINATION [J].
ABDELLATIF, MS .
ANALYTICAL LETTERS, 1994, 27 (13) :2601-2614
[2]   SYNTHETIC INORGANIC ION-EXCHANGE MATERIALS .32. STUDIES ON AN ARALDITE-BASED MEMBRANE OF CRYSTALLINE ANTIMONIC(V) ACID AS A NITRATE ION-SELECTIVE ELECTRODE [J].
AGRAWAL, S ;
ABE, M .
ANALYST, 1983, 108 (1287) :712-716
[3]   CRYSTALLINE INSOLUBLE SALTS OF POLYBASIC METALS .1. ION-EXCHANGE PROPERTIES OF CRYSTALLINE TITANIUM PHOSPHATE [J].
ALBERTI, G ;
CARDINIG.P ;
COSTANTI.U ;
TORRACCA, E .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1967, 29 (02) :571-&
[4]   CRYSTALLINE INSOLUBLE ACID SALTS OF TETRAVALENT METALS .34. HYDROGEN-AMMONIUM ION-EXCHANGE ON GAMMA-TITANIUM PHOSPHATE [J].
ALBERTI, G ;
BERNASCONI, MG ;
CASCIOLA, M ;
COSTANTINO, U .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1980, 42 (11) :1637-1640
[5]  
BADR IHA, 1995, ANAL CHIM ACTA, V310, P211, DOI 10.1016/0003-2670(95)00154-R
[6]  
BOSQUESENDRA JM, 1994, J AOAC INT, V77, P1224
[7]   NEW ENZYME SENSOR FOR SULFITE ANALYSIS IN SEA AND RIVER WATER SAMPLES [J].
CAMPANELLA, L ;
CIPRIANI, P ;
MARTINI, TM ;
SAMMARTINO, MP ;
TOMASSETTI, M .
ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) :32-41
[8]   SULFITE OXIDATION AT A PLATINUM GLASSY-CARBON ELECTRODE - DETERMINATION OF SULFITE BY ION-EXCLUSION CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION [J].
CASELLA, IG ;
MARCHESE, R .
ANALYTICA CHIMICA ACTA, 1995, 311 (02) :199-210
[9]  
COETZEE CJ, 1981, ION SELECTIVE ELECTR, V3, P105
[10]   AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF SULFITE IN THE PRESENCE OF A HIGH-CONCENTRATION OF THIOSULFATE [J].
COSANO, JS ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) :269-274