A monolithic silicon based integrated signal generation and detection system for monitoring DNA hybridisation

被引:35
作者
Bertolino, C
MacSweeney, M
Tobin, J
O'Neill, B
Sheehan, MM [1 ]
Coluccia, S
Berney, H
机构
[1] Univ Coll Cork, NMRC, Bioanalyt Microsyst, Cork, Ireland
[2] Univ Turin, Dept Chem, IFM, I-10125 Turin, Italy
[3] Newcastle Univ, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
electrochemiluminescence; DNA biosensor; PIN photodiode; point of care diagnostic;
D O I
10.1016/j.bios.2004.12.007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
(T)he aim of this work was to develop an integrated solution to DNA hybridisation monitoring for diagnostics on a monolithic silicon platform. A fabrication process was developed incorporating a gold initiation electrode patterned directly onto a PIN photodiode detector. Patterned interdigitated type electrodes exhibited the smallest reduction in photodiode sensitivity, therefore these were chosen as the ECL initiator design. A novel DNA hybridisation assay was developed based on the displacement of a partially mismatched cornplementary strand by a perfectly matched labelled complementary strand. Prehybridised thiolated oligonucleotide and unlabelled 25% mismatched oligonucleotide were assembled on the gold initiation electrode. On addition of the labelled perfectly complementary oligonucleotide. the mismatched strands were displaced and a signal was generated. The sensitivity of the photodiode to light emitted at 620 nm, the ruthenium emission wavelength, was determined and subsequently, the diode current response to light generated by flow addition of ruthenium solution was found to be measurable to a concentration of 10 fM. Prehybridised duplex DNA, consisting of thiolated oligonucleotide and ruthenium labelled complementary oligonucleotide. was assembled on the gold initiation electrode. The difference between the current measured during flow of buffer and the ECL coreactant TPA was three orders of magnitude, indicating that DNA assembled on the surface comprised sufficient ruthenium to generate a measurable signal. Finally, the displacement of unlabelled partial mismatch oligonucleotide from the sensor surface was monitored on addition of the ruthenium labelled perfectly complementary oligonucleotide in TPA flow and the measured photodiode current response was up to 50 times greater. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:565 / 573
页数:9
相关论文
共 33 条
[1]   Fiber-optic evanescent wave biosensor for the detection of oligonucleotides [J].
Abel, AP ;
Weller, MG ;
Duveneck, GL ;
Ehrat, M ;
Widmer, HM .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2905-2912
[2]  
BARD AJ, 1993, Patent No. 5221605
[3]  
BARD AJ, 1993, Patent No. 5238808
[4]  
BARD AJ, 1994, Patent No. 5310687
[5]   A DNA diagnostic biosensor: development, characterisation and performance [J].
Berney, H ;
West, J ;
Haefele, E ;
Alderman, J ;
Lane, W ;
Collins, JK .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :100-108
[6]   New developments in microarray technology [J].
Blohm, DH ;
Guiseppi-Elie, A .
CURRENT OPINION IN BIOTECHNOLOGY, 2001, 12 (01) :41-47
[7]   Quartz crystal microbalance study of DNA immobilization and hybridization for nucleic acid sensor development [J].
Caruso, F ;
Rodda, E ;
Furlong, DF ;
Niikura, K ;
Okahata, Y .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2043-2049
[8]   Analysing genetic information with DNA arrays [J].
Case-Green, SC ;
Mir, KU ;
Pritchard, CE ;
Southern, EM .
CURRENT OPINION IN CHEMICAL BIOLOGY, 1998, 2 (03) :404-410
[9]   Electrogenerated chemiluminescence 73: acid-base properties, electrochemistry, and electrogenerated chemiluminescence of neutral red in acetonitrile [J].
Choi, JP ;
Bard, AJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 573 (02) :215-225
[10]   Luminescence of Grignard compounds in electric and magnetic fields, and related electrical phenomena [J].
Dufford, RT ;
Nightingale, D ;
Gaddum, LW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1927, 49 :1858-1864