Optimization of X-ray phase-contrast imaging based on in-line holography

被引:23
作者
Wu, XZ
Liu, H
Yan, AM
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35233 USA
[2] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
[3] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
基金
美国国家卫生研究院;
关键词
X-ray coherence; X-ray phase-contrast imaging; in-line holography;
D O I
10.1016/j.nimb.2005.02.015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper introduces a newly conceived formalism for clinical in-line phase-contrast X-ray imaging. The new formalism applies not only to ideal "thin" objects analyzed in previous studies, but also applies to the real-world tissues used in actual clinical practice. Moreover we have identified the four clinically important factors that affect phase-contrast characteristics. These factors are: (1) body part attenuation, (2) the spatial coherence of incident X-rays from an X-ray tube, (3) the polychromatic nature of the X-ray source and (4) radiation dose to patients for clinical applications. Techniques of phase image-reconstruction based on the new X-ray in-line holography theory are discussed. Numerical simulations are described which were used to validate the theory. The design parameters of an optimal clinical phase-contrast mammographic imaging system which were determined based on the new theory, and validated in the simulations, are presented. The theory, image reconstruction algorithms, and numerical simulation techniques presented in this paper can be applied widely to clinical diagnostic X-ray imaging applications. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:563 / 572
页数:10
相关论文
共 19 条
[1]  
Born M., 1986, PRINCIPLES OPTICS
[2]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[3]  
GUIGAY JP, 1977, OPTIK, V49, P121
[4]   THE SEMICLASSICAL EVOLUTION OF WAVE-PACKETS [J].
LITTLEJOHN, RG .
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1986, 138 (4-5) :193-291
[5]  
Mandel L., 1995, EBL SCHWEITZER
[6]   PHASE-CONTRAST RADIOGRAPHS OF NONSTAINED RAT CEREBELLAR SPECIMEN [J].
MOMOSE, A ;
FUKUDA, J .
MEDICAL PHYSICS, 1995, 22 (04) :375-379
[7]   Characterization of a CCD-based digital x-ray imaging system for small-animal studies: properties of spatial resolution [J].
Ouandji, F ;
Potter, E ;
Chen, WR ;
Li, YH ;
Tang, D ;
Liu, H .
APPLIED OPTICS, 2002, 41 (13) :2420-2427
[8]   Contrast and resolution in imaging with a microfocus x-ray source [J].
Pogany, A ;
Gao, D ;
Wilkins, SW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) :2774-2782
[9]  
Shi MY, 2001, J X-RAY SCI TECHNOL, V10, P37
[10]   On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation [J].
Snigirev, A ;
Snigireva, I ;
Kohn, V ;
Kuznetsov, S ;
Schelokov, I .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12) :5486-5492