Characterization of a CCD-based digital x-ray imaging system for small-animal studies: properties of spatial resolution

被引:22
作者
Ouandji, F [1 ]
Potter, E
Chen, WR
Li, YH
Tang, D
Liu, H
机构
[1] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
[2] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
[3] Univ Cent Oklahoma, Dept Phys & Engn, Edmond, OK 73034 USA
[4] Univ Oklahoma, Dept Phys & Astron, Norman, OK 73019 USA
关键词
D O I
10.1364/AO.41.002420
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A digital x-ray imaging system was designed for small-animal studies. This system is a fiber-optics taper-coupled imaging system with two CCD arrays uniquely jointed, The x-ray source of the system has a small focal spot of 20 mum. This digital imaging system contains specially designed shelves to provide magnification levels, ranging from 1.5x to 5x. The system is characterized in terms of its properties of spatial resolution. An observer-based spatial resolution measurement was conducted with a line-pair target and a sector test pattern. The modulation transfer function of the system, with different magnifications, was studied by use of a 10-mum lead slit. The average resolutions at 50% and 5% modulations at 1x magnification were measured as 3.9 and 8.4 lp/mm, respectively, where lp indicates line pairs. With 5x magnification, the 50% and the 5% modulations provided 13.2- and 29.9-lp/mm, respectively, average spatial resolutions. The measurements showed consistency between the two individual CCD arrays; the difference in resolution between the two CCDs is less than 1%, even at high magnifications. (C) 2002 Optical Society of America.
引用
收藏
页码:2420 / 2427
页数:8
相关论文
共 30 条
[1]   An objective comparison of four digital intra-oral radiographic systems: sensitometric properties and resolution [J].
Araki, K ;
Endo, A ;
Okano, T .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) :76-80
[2]   Sinusoidal modulation analysis for optical system MTF measurements [J].
Boone, JM ;
Yu, T ;
Seibert, JA .
MEDICAL PHYSICS, 1996, 23 (12) :1955-1963
[3]   Determination of the presampled MTF in computed tomography [J].
Boone, JM .
MEDICAL PHYSICS, 2001, 28 (03) :356-360
[4]   DEVELOPMENT OF AN ANTHROPOMORPHIC BREAST PHANTOM [J].
CALDWELL, CB ;
YAFFE, MJ .
MEDICAL PHYSICS, 1990, 17 (02) :273-280
[5]  
Dainty JC., 1974, IMAGE SCI
[6]   Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography [J].
Floyd, CE ;
Warp, RJ ;
Dobbins, JT ;
Chotas, HG ;
Baydush, AH ;
Vargas-Voracek, R ;
Ravin, CE .
RADIOLOGY, 2001, 218 (03) :683-688
[7]   Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems [J].
Flynn, MJ ;
Samei, E .
MEDICAL PHYSICS, 1999, 26 (08) :1612-1623
[8]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[9]   BREAST RADIOGRAPHY - PHANTOM, EQUIPMENT PERFORMANCE, AND RADIATION DOSAGE COMPARISONS FOR 28 MAJOR MAMMOGRAPHY CENTERS IN THE MIDWEST [J].
GANNON, FE ;
FIELDS, T ;
GRIFFITH, CR ;
HUBBARD, LB ;
BROADBENT, MV ;
STANTON, L .
RADIOLOGY, 1983, 149 (02) :579-582
[10]   INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .1. MODULATION TRANSFER-FUNCTION [J].
GIGER, ML ;
DOI, K .
MEDICAL PHYSICS, 1984, 11 (03) :287-295