Thermal performance analysis according to wood flooring structure for energy conservation in radiant floor heating systems

被引:70
作者
Seo, Jungki [1 ]
Jeon, Jisoo [1 ]
Lee, Jeong-Hun [1 ]
Kim, Sumin [1 ]
机构
[1] Soongsil Univ, Sch Architecture, Bldg Environm & Mat Lab, Seoul 156743, South Korea
关键词
Wood flooring; Under-floor heating system; Thermal conductivity; Latent heat; Energy conservation; Building materials; FORMALDEHYDE EMISSION; BUILDINGS; KOREA;
D O I
10.1016/j.enbuild.2011.04.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this study was to reduce energy consumption, especially heating, in buildings. Improvements in the thermal conductivity of wood flooring, which was considered to decrease heating between floors and the indoor areas, were investigated. Wood flooring components such as solid-wood, high-density fiberboard (HDF), adhesives and polyethylene generally exhibit low thermal conductivity. The thermal conductivity and transfer performance of 21 replicates of wood flooring materials generally used in Korea were measured. The thermal conductivity was measured by using the guarded hot plate method. The thermal conductivities differed according to the structure of the floorings. Laminate wood flooring exhibited the highest thermal conductivity because of its high density and thin layers compared to the other floorings. The thermal transfer performance differed according to the installation method. The floating installation method exhibited a lower thermal transfer speed than the adhesion installation method because of its air layers and polyethylene form. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:2039 / 2042
页数:4
相关论文
共 20 条
[1]   Emission behavior of formaldehyde and TVOC from engineered flooring in under heating and air circulation systems [J].
An, Jae-Yoon ;
Kim, Sumin ;
Kim, Hyun-Joong ;
Seo, Janghoo .
BUILDING AND ENVIRONMENT, 2010, 45 (08) :1826-1833
[2]  
[Anonymous], 2007 INT PAN CLIM CH
[3]  
[Anonymous], CLIM CHANG 2001 SYNT
[4]   An estimation of energy and GHG emission intensity caused by energy consumption in Korea: An energy IO approach [J].
Chung, Whan-Sam ;
Tohno, Susumu ;
Shim, Sang Yul .
APPLIED ENERGY, 2009, 86 (10) :1902-1914
[5]   Tools for environmental assessment of the built environment [J].
Forsberg, A ;
von Malmborg, F .
BUILDING AND ENVIRONMENT, 2004, 39 (02) :223-228
[6]   Climate change impacts on building heating and cooling energy demand in Switzerland [J].
Frank, T .
ENERGY AND BUILDINGS, 2005, 37 (11) :1175-1185
[7]  
KANG IK, 2003, P 27 S HUM ENV SYST, P129
[8]   Thermal insulation properties of wood-based sandwich panel for use as structural insulated walls and floors [J].
Kawasaki, T ;
Kawai, S .
JOURNAL OF WOOD SCIENCE, 2006, 52 (01) :75-83
[9]   Comparison of formaldehyde emission from building finishing materials at various temperatures in under heating system; ONDOL [J].
Kim, S ;
Kim, HJ .
INDOOR AIR, 2005, 15 (05) :317-325
[10]   Comparison of standard methods and gas chromatography method in determination of formaldehyde emission from MDF bonded with formaldehyde-based resins [J].
Kim, S ;
Kim, HJ .
BIORESOURCE TECHNOLOGY, 2005, 96 (13) :1457-1464