Accuracy and validity of a combined heart rate and motion sensor for the measurement of free-living physical activity energy expenditure in adults in Cameroon

被引:87
作者
Assah, Felix K. [1 ]
Ekelund, Ulf [1 ]
Brage, Soren [1 ]
Wright, Antony [2 ]
Mbanya, Jean Claude [3 ]
Wareham, Nicholas J. [1 ]
机构
[1] Addenbrookes Hosp, Inst Metab Sci, Epidemiol Unit, MRC, Cambridge CB2 0QQ, England
[2] Med Res Council Human Nutr Res, Cambridge, England
[3] Univ Yaounde I, Fac Med & Biomed Sci, Yaounde, Cameroon
基金
英国惠康基金; 英国医学研究理事会;
关键词
Physical activity; energy expenditure; doubly labelled water; heart rate monitoring; accelerometry; sub-Saharan Africa; validity; accuracy; DOUBLY-LABELED-WATER; ALL-CAUSE MORTALITY; SUB-SAHARAN AFRICA; CARDIOVASCULAR-DISEASE; MOVEMENT SENSOR; ACCELEROMETRY; WOMEN; VALIDATION; MEN; CALORIMETRY;
D O I
10.1093/ije/dyq098
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background The increasing burden of non-communicable diseases in sub-Saharan Africa (SSA) warrants rigorous studies of contributing lifestyle factors. Combined heart rate (HR) and movement monitoring make it possible to objectively measure physical activity in free-living individuals. We examined the validity of a combined HR and motion sensor in estimating physical activity energy expenditure (PAEE) in free-living adults in rural and urban Cameroon compared with doubly-labelled water (DLW) as criterion. Methods PAEE was measured in 33 free-living rural and urban dwellers by DLW over 7 consecutive days. Simultaneously, the combined sensor recorded HR and uni-axial acceleration. Individual HR vs PAEE calibration was done by a step test. Branched equation modelling was used to estimate PAEE from HR and acceleration. Validity and accuracy of prediction were expressed as mean bias and root mean square error (RMSE). Agreement was analysed using Bland and Altman limits of agreement (LOA). Results There was no significant mean bias between PARE estimated from the combined sensor or measured by DLW [mean bias (standard error): -5.4 (5.1) kJ/kg/day; P = 0.3; RMSE = 29.3 kJ/kg/day]. The bias doubled for group compared with individual calibration of HR [-9.1 (5.0) kJ/kg/day, P = 0.08]. PAEE prediction was more accurate in urban compared with rural volunteers. The 95% LOAs between predicted and measured PAEE were similar to 50-60 kJ/kg/day above or below perfect agreement. Conclusions Combined HR and movement sensing is a valid method for estimating free-living PAEE on group level in adults in SSA.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 56 条
[1]  
[Anonymous], 1996, Physical activity and health: A report of the Surgeon General
[2]  
[Anonymous], [No title captured]
[3]   Predicting Physical Activity Energy Expenditure Using Accelerometry in Adults From Sub-Sahara Africa [J].
Assah, Felix K. ;
Ekelund, Ulf ;
Brage, Soren ;
Corder, Kirsten ;
Wright, Antony ;
Mbanya, Jean C. ;
Wareham, Nicholas J. .
OBESITY, 2009, 17 (08) :1588-1595
[4]  
AVONS P, 1988, EUR J CLIN NUTR, V42, P185
[5]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[6]   Within- and between-subject variation in energy expenditure measured by the doubly-labelled water technique: implications for validating reported dietary energy intake [J].
Black, AE ;
Cole, TJ .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2000, 54 (05) :386-394
[7]   Influences of cardiorespiratory fitness and other precursors on cardiovascular disease and all-cause mortality in men and women [J].
Blair, SN ;
Kampert, JB ;
Kohl, HW ;
Barlow, CE ;
Macera, CA ;
Paffenbarger, RS ;
Gibbons, LW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (03) :205-210
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living [J].
Brage, S ;
Brage, N ;
Ekelund, U ;
Luan, J ;
Franks, PW ;
Froberg, K ;
Wareham, NJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (05) :517-524
[10]   Reliability and validity of the combined heart rate and movement sensor Actiheart [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wareham, NJ .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (04) :561-570