Radiographic and digital imaging in periodontal practice

被引:43
作者
Hausmann, E
机构
[1] Comp Anal Plus, Amherst, NY USA
[2] SUNY Buffalo, Dept Oral Biol, Buffalo, NY 14260 USA
关键词
radiography; dental; digital; review literature;
D O I
10.1902/jop.2000.71.3.497
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This review defines terms such as accuracy, validity, and reliability, which are used to describe the quality of methods for taking x-rays and for analyzing digital images. Values for these parameters are described for techniques of taking standardized x-rays such as ear-rod fixation and fixation by use of teeth with a dental impression. In addition, values are given for linear measurements on digitized images and for quantitative image subtraction. Differences are addressed between quantitative subtraction with a reference ramp and relative subtraction using the computer-assisted densitometric image analysis (CADIA) system. The relationship between radiographic bone height and clinical attachment level is also discussed. Finally, present and future use in the periodontal office of linear radiographic measurements on digital images and digital subtraction is discussed.
引用
收藏
页码:497 / 503
页数:7
相关论文
共 69 条
[11]  
Brägger U, 1998, J PERIODONTOL, V69, P967
[12]   EVALUATION OF A SIMPLE MODIFIED RADIOGRAPHIC ALIGNMENT SYSTEM FOR ROUTINE USE [J].
CARPIO, LC ;
HAUSMANN, E ;
DUNFORD, RG ;
ALLEN, KM ;
CHRISTERSSON, LA .
JOURNAL OF PERIODONTOLOGY, 1994, 65 (01) :62-67
[13]  
Christgau M, 1998, J PERIODONTAL RES, V33, P138
[14]  
Clerehugh V, 1984, Community Dent Health, V1, P33
[15]   Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: Radiographic results [J].
Cochran, DL ;
Nummikoski, PV ;
Higginbottom, FL ;
Hermann, JS ;
Makins, SR ;
Buser, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :240-252
[16]  
Cochran DL, 1997, INT J ORAL MAX IMPL, V12, P739
[17]   OBJECTIVE AND SUBJECTIVE EVALUATIONS OF KODAK EKTASPEED-PLUS DENTAL-X-RAY FILM [J].
CONOVER, GL ;
HILDEBOLT, CF ;
ANTHONY, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 79 (02) :246-250
[18]   EFFECTS OF SMALL-ANGLE DISCREPANCIES ON INTERPRETATIONS OF SUBTRACTION IMAGES [J].
DAVIS, M ;
ALLEN, KM ;
HAUSMANN, E .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (03) :397-400
[19]   A METHOD FOR THE GEOMETRIC AND DENSITOMETRIC STANDARDIZATION OF INTRAORAL RADIOGRAPHS [J].
DUCKWORTH, JE ;
JUDY, PF ;
GOODSON, JM ;
SOCRANSKY, SS .
JOURNAL OF PERIODONTOLOGY, 1983, 54 (07) :435-440
[20]  
Dunn S M, 1992, Dentomaxillofac Radiol, V21, P142