Characterization of antibody-antigen interactions: Comparison between surface plasmon resonance measurements and high-mass matrix-assisted laser desorption/ionization mass spectrometry

被引:31
作者
Bich, Claudia [1 ]
Scott, Mike [2 ]
Panagiotidis, Andreas [3 ]
Wenzel, Ryan J. [1 ,4 ]
Nazabal, Alexis [1 ,4 ]
Zenobi, Renato [1 ]
机构
[1] ETH, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
[2] Funct Genom Ctr Zurich, CH-8057 Zurich, Switzerland
[3] ETH, IMSB, CH-8093 Zurich, Switzerland
[4] Coval X, CH-8005 Zurich, Switzerland
关键词
matrix-assisted laser desorption/ionization (MALDI); cross-linking; surface plasmon resonance (SPR); antibody-antigen interaction;
D O I
10.1016/j.ab.2007.11.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The interaction between the bovine prion protein (bPrP) and a monoclonal antibody, 1E5, was studied with high-mass matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) and surface plasmon resonance (SPR). In the case of MS a cross-linking stabilization was used prior to the analysis, whereas for SPR the antibody was immobilized and bPrP was injected. We compared the determination of parameters such as the epitope, the kinetics and binding strength, and the capacity of the antigen to bind two different antibodies. The two methods are highly complementary. SPR measurements require a lower amount of sample but are more time-consuming due to all of the necessary side steps (e.g., immobilization, regeneration). High-mass MALDI NIS needs a higher overall amount of sample and cannot give direct access to the kinetic constants, but the analysis is faster and easier compared with SPR. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 37 条
[1]   Recent developments in electrospray ionisation mass spectrometry: noncovalently bound protein complexes [J].
Ashcroft, AE .
NATURAL PRODUCT REPORTS, 2005, 22 (04) :452-464
[2]  
BERG JM, 2006, BIOCHEMISTRY-US, P86
[3]  
BERG JM, 2006, BIOCHEMISTRY-US, P88
[4]   Immunodiagnosis of Besnoitia besnoiti infection by ELISA and Western blot [J].
Cortes, H. C. E. ;
Nunes, S. ;
Reis, Y. ;
Staubli, D. ;
Vidal, R. ;
Sager, H. ;
Leitao, A. ;
Gottstein, B. .
VETERINARY PARASITOLOGY, 2006, 141 (3-4) :216-225
[5]   Characterizing high-affinity antigen/antibody complexes by kinetic- and equilibrium-based methods [J].
Drake, AW ;
Myszka, DG ;
Klakamp, SL .
ANALYTICAL BIOCHEMISTRY, 2004, 328 (01) :35-43
[6]  
Fagerstam L G, 1990, J Mol Recognit, V3, P208, DOI 10.1002/jmr.300030507
[7]  
Farmer TB, 1998, J MASS SPECTROM, V33, P697, DOI 10.1002/(SICI)1096-9888(199808)33:8<697::AID-JMS711>3.0.CO
[8]  
2-H
[9]   MASS DISCRIMINATION IN MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY - A STUDY USING CROSS-LINKED OLIGOMERIC COMPLEXES [J].
FARMER, TB ;
CAPRIOLI, RM .
JOURNAL OF MASS SPECTROMETRY, 1995, 30 (09) :1245-1254
[10]   ASSESSING THE MULTIMERIC STATES OF PROTEINS - STUDIES USING LASER DESORPTION MASS-SPECTROMETRY [J].
FARMER, TB ;
CAPRIOLI, RM .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (12) :796-800