Intracranial aneurysms at MR angiography: Effect of computer-aided diagnosis on radiologists' detection performance

被引:38
作者
Hirai, T
Korogi, Y
Arimura, H
Katsuragawa, S
Kitajima, M
Yamura, M
Yamashita, Y
Doi, K
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto 8608556, Japan
[2] Univ Occupat & Environm Hlth, Dept Radiol, Sch Med, Kitakyushu, Fukuoka 807, Japan
[3] Kyushu Univ, Dept Hlth Sci, Fukuoka 812, Japan
[4] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
10.1148/radiol.2372041734
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To retrospectively evaluate the effect of computer-aided detection (CAD) on radiologists' performance in detection of intracranial aneurysms with magentic resonance (MR) angiography. MATERIALS AND METHODS: The institutional review board approved this study and did not require patient informed consent. Fifty maximum intensity projection MR angiograms in 50 patients were used for observer performance study. The group included 22 patients (age range, 43-86 years; mean, 60.2 years; 6 men and 16 women) with intracranial aneurysms and 28 patients (age range, 32-80 years; mean, 58.8 years; 10 men and 18 women) without aneurysms. The MR angiograms were obtained with three-dimensional time-of-flight 1.5-T MR imaging. Fifteen radiologists, including eight neuroradiologists and seven general radiologists, participated in the observer performance test. They interpreted the angiograms first without and then with the aid of the computer output by using an automated computerized scheme. The observers' performance without and with the computer output was evaluated with receiver operating characteristic analysis. RESULTS: For all 15 observers, average area under the receiver operating characteristic curve (A(z)) value for detection of aneurysms was increased significantly from 0.931 to 0.983 (P = .001) when they used the computer output. A(z) values for general radiologists and neuroradiologists increased from 0.894 to 0.983 (P = .022) and from 0.963 to 0.984 (P = .014), respectively. Improvement in the performance of general radiologists in terms of the A(z) value was much greater than that of neuroradiologists. Performance of general radiologists with CAD (A(z) = 0.983) slightly exceeded that of neuroradiologists without CAD (A(z) = 0.963) (P = .048). CONCLUSION: CAD improved neuroradiologists' and general radiologists' performance for detection of intracranial aneurysms with MR angiography; improvement was greater for general radiologists than it was for neuroradiologists. (c) RSNA, 2005
引用
收藏
页码:605 / 610
页数:6
相关论文
共 21 条
[1]   Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional magnetic resonance angiography [J].
Arimura, H ;
Li, Q ;
Korogi, Y ;
Hirai, T ;
Abe, H ;
Yamashita, Y ;
Katsuragawa, S ;
Ikeda, R ;
Doi, K .
ACADEMIC RADIOLOGY, 2004, 11 (10) :1093-1104
[2]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[3]  
Baba Y, 2000, EUR RADIOL, V10, pS362
[4]   QUANTIFICATION OF OPERATIVE BENEFIT FOR UNRUPTURED CEREBRAL ANEURYSMS - A THEORETICAL APPROACH [J].
CHANG, HS ;
KIRINO, T .
JOURNAL OF NEUROSURGERY, 1995, 83 (03) :413-420
[5]   Can computer-aided detection with double reading of screening mammograms help decrease the false-negative rate? Initial experience [J].
Destounis, SV ;
DiNitto, P ;
Logan-Young, W ;
Bonaccio, E ;
Zuley, ML ;
Willison, KM .
RADIOLOGY, 2004, 232 (02) :578-584
[6]   Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center [J].
Freer, TW ;
Ulissey, MJ .
RADIOLOGY, 2001, 220 (03) :781-786
[7]   Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs [J].
Kobayashi, T ;
Xu, XW ;
MacMahon, H ;
Metz, CE ;
Doi, K .
RADIOLOGY, 1996, 199 (03) :843-848
[8]   Intracranial aneurysms: Diagnostic accuracy of MR angiography with evaluation of maximum intensity projection and source images [J].
Korogi, Y ;
Takahashi, M ;
Mabuchi, N ;
Nakagawa, T ;
Fujiwara, S ;
Horikawa, Y ;
Miki, H ;
OUchi, T ;
Shiga, H ;
Shiokawa, Y ;
Watabe, T ;
Furuse, M .
RADIOLOGY, 1996, 199 (01) :199-207
[9]   INTRACRANIAL ANEURYSMS - DIAGNOSTIC-ACCURACY OF 3-DIMENSIONAL, FOURIER-TRANSFORM, TIME-OF-FLIGHT MR-ANGIOGRAPHY [J].
KOROGI, Y ;
TAKAHASHI, M ;
MABUCHI, N ;
MIKI, H ;
FUJIWARA, S ;
HORIKAWA, Y ;
NAKAGAWA, T ;
OUCHI, T ;
WATABE, T ;
SHIGA, H ;
FURUSE, M .
RADIOLOGY, 1994, 193 (01) :181-186
[10]   SURGERY OF UNRUPTURED, ASYMPTOMATIC ANEURYSMS - A DECISION-ANALYSIS [J].
LEBLANC, R ;
WORSLEY, KJ .
CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1995, 22 (01) :30-35