Isolation and quantification of volatiles in fish by dynamic headspace sampling and mass spectrometry

被引:61
作者
Refsgaard, HHF [1 ]
Haahr, AM [1 ]
Jensen, B [1 ]
机构
[1] Tech Univ Denmark, Danish Inst Fisheries Res, Dept Seafood Res, DK-2800 Lyngby, Denmark
关键词
dynamic headspace sampling; volatiles; aldehydes; salmon; fresh fish;
D O I
10.1021/jf9807770
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A dynamic headspace sampling method for isolation of volatiles in fish has been developed. The sample preparation involved freezing of fish tissue in liquid nitrogen, pulverizing the tissue, and sampling of volatiles from an aqueous slurry of the fish powder. Similar volatile patterns were determined by use of this sample preparation method and for samples chewed for 10 s. Effects of sampling time, temperature, and purge flow on level of volatiles were tested. Purging at 340 mL/min for 30 min at 45 degrees C was found to be optimal. Detection Emits for a number of aldehydes were 0.2-2.7 mu g/kg. Levels of volatiles are given for fresh salmon, cod, saithe, mackerel, and redfish.
引用
收藏
页码:1114 / 1118
页数:5
相关论文
共 18 条
[1]  
Alasalvar C, 1997, ACS SYM SER, V674, P39
[2]  
[Anonymous], TECHNIQUES ANAL FOOD
[3]   ANALYSIS OF VOLATILE COMPONENTS IN FRESH GRAPEFRUIT JUICE BY PURGE-AND-TRAP GAS-CHROMATOGRAPHY [J].
CADWALLADER, KR ;
XU, Y .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (03) :782-784
[4]   Estimate of gas chromatographic blanks - Application to detection limits evaluation as recommended by IUPAC [J].
Casado, AG ;
Rodriguez, LC ;
Hernandez, EA ;
Vilchez, JL .
JOURNAL OF CHROMATOGRAPHY A, 1996, 726 (1-2) :133-139
[5]   SYSTEMATIC-ERRORS WITH THE USE OF INTERNAL STANDARD CALIBRATION IN GAS-CHROMATOGRAPHIC HEADSPACE ANALYSIS [J].
DROZD, J ;
VODAKOVA, Z ;
KOUPIL, P .
JOURNAL OF CHROMATOGRAPHY, 1990, 518 (01) :1-8
[6]  
Jensen B, 1997, METHODS TO DETERMINE THE FRESHNESS OF FISH IN RESEARCH AND INDUSTRY, P70
[7]   ESTIMATION OF THE LIMIT OF DETECTION IN CHROMATOGRAPHY [J].
KNOLL, JE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (09) :422-425
[8]   ESTIMATION OF THE LOWER LIMIT OF QUANTITATION, A METHOD DETECTION PERFORMANCE PARAMETER FOR BIOMEDICAL ASSAYS, FROM CALIBRATION CURVES [J].
KUCHARCZYK, N .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 612 (01) :71-76
[9]  
LINDSAY R C, 1990, Food Reviews International, V6, P437
[10]   DETECTION OF ODOR DEFECTS IN BOILED COD AND TROUT BY GAS-CHROMATOGRAPHY OLFACTOMETRY OF HEADSPACE SAMPLES [J].
MILO, C ;
GROSCH, W .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (02) :459-462