Implantable defibrillator diagnostic storage capabilities: Evolution, current status, and future utilization

被引:18
作者
Sarter, BH
Callans, DJ
Gottlieb, CD
Schwartzman, DS
Marchlinski, FE
机构
[1] Allegheny Univ Hlth Sci Hosp, Philadelphia, PA 19129 USA
[2] Presbyterian Med Ctr, Philadelphia Heart Inst, Philadelphia, PA 19104 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 06期
关键词
implantable cardioverter defibrillator; ventricular tachycardia; ventricular fibrillation; stored electrograms;
D O I
10.1111/j.1540-8159.1998.tb00189.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There has been a rapid and significant evolution in the stored diagnostic information available from implantable cardioverter defibrillators (ICDs). The diagnostic information available in current generation ICDs has greatly enhanced the clinicians' ability to determine the rhythm triggering device therapy as well as to identify potential problems with the ICD system. Furthermore, this information may be useful in identifying triggers of ventricular arrhythmias in patients at high risk for sudden death. The history, evolution, value, and limitations of the stored diagnostic capabilities of implantable defibrillators are discussed.
引用
收藏
页码:1287 / 1298
页数:12
相关论文
共 36 条
[1]   CIRCADIAN VARIATION OF PRIMARY CARDIAC-ARREST OR SUDDEN CARDIAC DEATH IN PATIENTS AGED 62 TO 100 YEARS (MEAN 82) [J].
ARONOW, WS ;
AHN, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (16) :1455-1456
[2]   Clinical relevance of stored electrograms for implantable cardioverter-defibrillator (ICD) troubleshooting and understanding at mechanisms for ventricular tachyarrhythmias [J].
Auricchio, A ;
Hartung, W ;
Geller, C ;
Klein, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 :33-40
[3]  
BACH SM, 1989, J AM COLL CARDIOL, V13, P65
[4]   COMPARISON OF INITIAL DETECTION AND REDETECTION OF VENTRICULAR-FIBRILLATION IN A TRANSVENOUS DEFIBRILLATOR SYSTEM WITH AUTOMATIC GAIN-CONTROL [J].
BERUL, CI ;
CALLANS, DJ ;
SCHWARTZMAN, DS ;
PREMINGER, MW ;
GOTTLIEB, CD ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (02) :431-436
[5]   RESULTS AND REALISTIC EXPECTATIONS WITH TRANSVENOUS LEAD SYSTEMS [J].
BLOCK, M ;
HAMMEL, D ;
ISBRUCH, F ;
BORGGREFE, M ;
WIETHOLT, D ;
HACHENBERG, T ;
SCHELD, HH ;
BREITHARDT, G .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (04) :665-670
[6]   USE OF BIPOLAR RECORDINGS FROM PATCH-PATCH AND RATE SENSING LEADS TO DISTINGUISH VENTRICULAR-TACHYCARDIA FROM SUPRAVENTRICULAR RHYTHMS IN PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
CALLANS, DJ ;
HOOK, BG ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1917-1922
[7]   UNIQUE SENSING ERRORS IN 3RD-GENERATION IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS [J].
CALLANS, DJ ;
HOOK, BG ;
KLEIMAN, RB ;
MITRA, RL ;
FLORES, BT ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (04) :1135-1140
[8]   EFFECT OF RATE AND COUPLING INTERVAL ON ENDOCARDIAL-R WAVE AMPLITUDE VARIABILITY IN PERMANENT VENTRICULAR SENSING LEAD SYSTEMS [J].
CALLANS, DJ ;
HOOK, BG ;
MARCHLINSKI, FE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (03) :746-750
[9]  
CALLANS DJ, 1991, AM J CARDIOL, V67, P5054
[10]   AMBULATORY SUDDEN CARDIAC DEATH - MECHANISMS OF PRODUCTION OF FATAL ARRHYTHMIA ON THE BASIS OF DATA FROM 157 CASES [J].
DELUNA, AB ;
COUMEL, P ;
LECLERCQ, JF .
AMERICAN HEART JOURNAL, 1989, 117 (01) :151-159